Changing Basic Settings - Siemens SITRANS MAG 6000 I Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS MAG 6000 I:
Table of Contents

Advertisement

Commissioning

6.4 Changing basic settings

5. Use select key
6. Press lock/unlock key
7. Press top up key
The factory-set password is 1000, but it can be changed to any value between 1000 and 9999.
Factory setting of password can be re-established as follows:
1. Switch off power supply.
2. While pressing top up key
3. Release top up key
6.4
Changing basic settings
In the basic settings menu it is possible to set the following parameters:
Parameter
Main frequency
Flow direction
Customer units
Q
max
Q
max
Totalizer
Low flow cut-off
Empty pipe cut-off
Velocity unit
Error level
Note
Totalizer 2 is not visible when batch is selected as digital output.
44
and change key
two times to exit setup mode.
after 10 sec.
Description
Selection of main power supply frequency corresponding to the country in which
the flowmeter is installed (e.g. 60 Hz in America).
Selection of correct flow direction in pipe.
Setting of user defined volume and time units.
Setting of measuring range, analog outputs and frequency output. Also individ‐
ual dimension-dependent setting of value, decimal point, unit and time.
2
Setting of measuring range, analog outputs and frequency output. Also individ‐
ual dimension-dependent setting of value, decimal point, unit and time. This
menu is only visible if chosen as external digital input.
Setting of unit and decimal point.
Setting of a percentage of selected Q
fluctuations in display and all outputs.
When set to "On" the alarm will indicate when sensor is running empty. All read‐
ings, display and outputs, will indicate zero.
Setting of velocity unit per time unit
Selecting error level at which flowmeter will detect an error.
to change password.
to confirm new password.
- switch on power supply.
. This filters noise in installation reducing
max
SITRANS MAG 6000 I/6000 I Ex de
Operating Instructions, 08/2018, A5E02083319-AH

Advertisement

Table of Contents
loading

Table of Contents