CRS-170A L-Band 1:1 Redundancy Switch
Modem and Switch Configuration
4.7
Configure the CDM-710GLs, CDM-710s, or CDM-700s for 1:1
Redundancy
CDM-710G/710GL Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM710G)
CDM-710 Broadcast Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM710.IOM)
CDM-700 Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM700.IOM)
For correct operation of the CRS-170A, the CDM-710GL, -710, and -700 modems must have
the following installed:
For the CDM-710GL:
o Firmware Version 5.1.1 (or higher)
For the CDM-710:
o Firmware Version 2.4.1 (or higher)
o Hardware Revision A (chassis with round-buttoned keypad)
For the CDM-700:
o Firmware Version 1.1.6 (or higher)
o Hardware Revision A (chassis with round-buttoned keypad)
Note that Hardware upgrades are possible only for the CDM-710 or CDM-700 Rev. A version
chassis and later – 1:1 redundancy operation is not available with hardware versions prior to
Rev. A.
If your modems do not meet these requirements, contact Comtech EF Data Product
Support. You may download free Firmware updates from the Comtech EF Data web site.
Hardware revision upgrades must be performed at Comtech EF Data.
Modem configuration, monitor and control are possible through local or remote means:
Local Control – Use the modem front panel to fully configure, monitor, and control the modem
operation:
o The LEDs indicate, in a summary fashion, the status of the modem.
o The VFD (Vacuum fluorescent Display) is an active display showing two lines of 24
characters each. It produces a blue light with adjustable brightness. Nested menus
display all available options and prompt you to carry out a required action.
o The keypad comprises six individual keyswitches. The keys have a positive 'click' action
that provides tactile feedback. Enter data via the keypad. Data, prompts, and messages
are displayed on the VFD.
Serial Remote Control – Configuration, monitoring and control of redundant systems is possible
via remote means over an RS-485 multi-drop bus using Windows Command-Line, where data is
transmitted in asynchronous serial form using ASCII characters.
Ethernet Remote Control – Configuration, monitoring and control of redundant systems is
possible via remote means over an Ethernet connection using the CDM-7XX HTTP Interface.