Advanced Vsat Cdm-850 Or Cdm-840 Operation In 1:1 Redundancy - Comtech EF Data CRS-170A Installation And Operation Manual

L-band 1:1 redundancy switch, accessory product for use only with comtech ef data cdm-625a, cdm-625, h64/h32/h16/h8 heights remote gateways, cdm-850, cdm-840, cdm-760, cdm-750, cdm-570al, cdm-570l, cdm-710gl, cdm-710, cdm-700, cdm-600l clm-9600l, and sdm-
Table of Contents

Advertisement

CRS-170A L-Band 1:1 Redundancy Switch
Modem and Switch Configuration
4.4

Advanced VSAT CDM-850 or CDM-840 Operation in 1:1 Redundancy

CDM-850 Remote Router Installation and Operation Manual (CEFD P/N MN-CDM850)
CDM-840 Remote Router Installation and Operation Manual (CEFD P/N MN-CDM840)
The Advanced VSAT CDM-850 and CDM-840 Remote Routers automatically detect connection to a 1:1
redundancy system. With both units automatically configured for 1:1 operation, the online unit keeps
the offline unit updated as online unit configuration changes occur.
If you choose to manually force backup of the online unit, you must execute the switchover by using the
Redundancy section of the online unit HTTP Interface 'Utility | Utility' page. Figure 4-3 shows an
example of this page, which is subject to update.
Figure 4-3. Advanced VSAT CDM-850 or CDM-840 HTTP Interface
If the unit is part of a 1:1 redundant pair and the unit is currently online, click [Force Redundancy
Switch] to force this currently active unit to switch to standby mode.
Example (Page Banner, VFP NOT SHOWN)
4–7
MN/CRS170A.IOM
Revision 14
'Utility | Utility'