Summary Of Specifications - Comtech EF Data CRS-170A Installation And Operation Manual

L-band 1:1 redundancy switch, accessory product for use only with comtech ef data cdm-625a, cdm-625, h64/h32/h16/h8 heights remote gateways, cdm-850, cdm-840, cdm-760, cdm-750, cdm-570al, cdm-570l, cdm-710gl, cdm-710, cdm-700, cdm-600l clm-9600l, and sdm-
Table of Contents

Advertisement

CRS-170A L-Band 1:1 Redundancy Switch
Introduction
1.4

Summary of Specifications

Equipment Type
Manufacturer
Supported Comtech EF Data Modems
Operating Modes
Architecture
Switch Conditions
IF Switching / Splitting
BUC Power Switching
BUC 10 MHz Reference Switching
BUC FSK Comms Switching
LNB Power Switching
LNB 10 MHz Reference Switching
Tx-Rx Isolation
IF Impedance
IF Connectors
IF Frequency Range
L-Band 1:1 Redundancy Switch
Comtech EF Data, Tempe, Arizona
CDM-625A or CDM-625 Advanced Satellite Modem with/without
optional IP Packet Processor
H64/H32/H16/H8 Heights Remote Gateway
Advanced VSAT CDM-850 or CDM-840 Remote Router
CDM-760 Advanced High-Speed Trunking Modem
CDM-750 Advanced High-Speed Trunking Modem
CDM-570AL L-Band Satellite Modem with/without optional IP Packet
Processor
CDM-570L L-Band Satellite Modem with/without optional IP Module
CDM-710GL L-Band High-Speed Satellite Modem
CDM-710 L-Band Broadcast Satellite Modem
CDM-700 L-Band Satellite Modem
CDM-600L (CLM-9600L) with CRS-150 1:1 Data Switch
SDM-300L3 with SMS-301 1:1 Data Switch
Fully automatic under control of supporting 1:1 switch.
Manual under control of supporting 1:1 switch.
Full bridging architecture when supported by CRS-150, or SMS-301
data switching and control, with configuration synchronization.
Tx redundancy supports all BUC interface signals (RF, 10 MHz
reference, FSK communications, and power supply)
Rx IF signal fed to both Online and Backup units. Rx switching
supports all LNB interface signals (RF, 10 MHz reference, and power
supply.)
Tx/Rx switching follows state of supporting data switching via control input
from data switch.
Tx IF: Switched by RF relay (1.5 dB max loss, 40 dB min ON/OFF
isolation)
Rx IF: Passive power splitting (7 dB max loss)
Switched by power relay (60VDC max, 4A max)
Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)
Switched by relay (70dB min ON/OFF isolation)
Switched by power relay (28 VDC max)
Switched by relay (1 dB max loss)
90dB min, 950-2250 MHz
Optimized for 50Ω (> 10 dB return loss on external IF ports)
50Ω Type N Female
950-2250 MHz