Port Monitoring - ORiNG IPS-3082GC-AT User Manual

Industrial managed ethernet switch
Table of Contents

Advertisement

Undersize
Fragments
Oversize
Jabber
InMACRcvErr
InFCSErr
Collisions
Late

5.1.14.5 Port Monitoring

Port monitoring function supports TX (egress) only, RX (ingress) only, and both TX/RX
monitoring. TX monitoring sends any data that egress out checked TX source ports to a
selected TX destination port as well. RX monitoring sends any data that ingress in checked
RX source ports out to a selected RX destination port as well as sending the frame where it
normally would have gone. Note that keep all source ports unchecked in order to disable port
monitoring.
ORing Industrial Networking Corp
half-duplex only.
Total frames received with a length of less than 64 octets but with
a valid FCS.
Total frames received with a length of more than 64 octets and
with a invalid FCS.
Total frames received with a length of more than MaxSize octets
but with a valid FCS.
Total frames received with a length of more than MaxSize octets
but with an invalid FCS.
Total frames received with an RxErr signal from the PHY.
Total frames received with a CRC error not counted in Fragments,
Jabber or RxErr.
The number of collision events seen by MAC not including those
conted in Single, Multiple, Excessive or Late. This counter is
applicable in half-duplex only.
The number of times a collision is detected later than 512
bits-times into the transmission of a frame. This counter is
applicable in half-duplex only.
Port monitoring interface
IPS-3082GC-AT User's Manual
84

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents