Clean The Microscope - Promax Prolite-41 User Manual

Optical fibre fusion splicer
Hide thumbs Also See for Prolite-41:
Table of Contents

Advertisement

ATTENTION:
Do not touch the electrode tip. When cleaning, do not overexert or
using hard object (such as blades) to clean the V-groove in order
to avoid damaging the V-groove, which can cause breakdown.

Clean the Microscope

3.3.2
Fibre Fusion Splicer use image processing system to observe the optical fibre. If
the microscope lens get dirty, it will affect observations, leading to poor fusion
splicer results. So the microscope lens should be cleaned regularly, to maintain
the cleanliness of the lens. The specific process is as follows:
Turn off the splicer power, and open windproof cover.
Use cotton swab dipped in alcohol to gently wipe the lens, as shown in
Figure 32.
Then wipe the residual alcohol with clean, dry cotton swab, after that,
check the microscope lens whether it is tidy.
Turn on the power to observe whether there is dust on the image, if
there is, re-clean the lens.
ATTENTION:
When cleaning, don't touch the electrodes, don't use hard objects
to touch the lens.
November 2018
Figure 32. Clean the Microscope.