Power saving mode
Set automatic dormancy or shutdown.
Silent Mode
Turn up or down the buzzer.
Function settings menu description
►
Figure 10. Function Settings Menu.
Sleeve heating mode
Set the sleeve heating time, typical heating time 31 seconds (60mm),
24 seconds (40mm).
Fast ArcTest Mode
If this is set "on", after splice is completed, the equipment adjusts arc
current and tension test.
Arc compensation
If this factor is set "on", automatically adjust the arc current.
Tension Test
If this is set "on", after splice is completed, the equipment will restore and
tension test will perform itself.
Reset Waiting Time
If the Tension test is set "off" , the system will restore the equipment after
the waiting time is over.
Auto Starting
If it is set "on", it will splice when the cover is lid.
Auto Heating
If it is set "on", it starts heating when the cover is lid.
10
Page
November 2018