Abnormal splice or high loss estimate phenomena and solutions are shown in
Table 3.
Phenomena
Fibre core axis mismatch
Fibre core angle error
Bubbles
Fibre Separation
Thick
Thin
Line
November 2018
Reason
Dust on V-groove or fibre
presser foot.
Image detection problem.
Dust on V-groove or fibre
presser foot.
Poor fibre head face angle.
Fibre is placed incorrectly.
Poor fibre head face angle.
Dust on Fibre head face.
Low Pre-splice current or
short-time pre-splice.
Low splice current or short-
time arc.
Splice propulsion force is
not enough.
Splice
propulsion
slow.
Spice current is too high or
arc time is too long.
The splice propulsion force is
excessive.
The splice propulsion force
is not enough.
Splice current is excessive.
Splice current is too small.
Table 3. Abnormal Alignment Note.
Solutions
Clean V-groove and fibre
presser foot.
If it appears repeatedly,
users need to do "Detect
system parameters".
Clean the lens and light
source.
Clean V-groove and fibre
presser foot.
Re-cleave fibre.
Replace fibre.
Re-cleave fibre.
Re-clean fibre.
Increase "Pre-splice
Current" or "Pre-splice
Time".
Increase "Splice Current" or
"Splice Time".
Do "Detect system
parameters".
is
too
Decrease "Pre-splice
Current" or "Pre-splice
Time".
Decrease
then do "Arc Correction" test.
Increase "Overlap Length",
then
do
test.
Decrease "Splice Current".
Increase "Splice Current".
"Overlap
Length",
"Arc
Correction"