Fibre Cleaving; Place Optical Fibre - Promax Prolite-41 User Manual

Optical fibre fusion splicer
Hide thumbs Also See for Prolite-41:
Table of Contents

Advertisement

2.5.4

Fibre Cleaving

Open the Cleaver cover and place the fibre with clamp into the cleaving
slot and keep the optical fibre vertical with the cleaver surface and keep
30mm of the fibre outside the clamp.
Press forward the fibre clamp and ensure the forefront of the clamp lies
closely with the cleaving slot. If not, the fibre can be longer than
expected.
Press down the fibre cover to cleave.
Open the cover and take away the cleaved fibre.
Take out the scrap and put into scrap box.
ATTENTION:
When cutting head face is not qualified or the cleaving cannot be
down, please adjust the blade of cleaver.
2.5.5

Place Optical Fibre

Open windproof cover to check whether the v-groove is clean or not. If
not, cleaning shall be down. Refer to chapter 3.4.1.
Place cleaved fibre (with clamp) into both-sided clamp slot and ensure it
is in the v-groove.
Note: The 0.9R clamp goes upside down (see figure).
Observe whether the fibre head face is between the electrode tip and the
v-groove and near the electrodes; if not, remake fibre.
Press the windproof cover lightly.