Entry And Change Of Data; (I) Entry And Change Of Preset Data - Ikegami HTM-1505R Operation Manual

Multl-foriviat color monitor
Hide thumbs Also See for HTM-1505R:
Table of Contents

Advertisement

9,
HTM-1505R/HTM-1505CS
4.4 Entry and Change of Data
(1) Entry and change of preset data
(Example-I
I
Change ofl-·l.PHASE, I-I.CENT, V.CENT, WIDTH, HEIGHT, TRAPEZOID, SIDE PIN
Set SCAN size to UNDER SCAN mode by means of SCAN switch, and
display I 0-division cross hatching marker by means of MARKER switch.
Pressing CHANGE PRESET switch blinks PRESET switch.
[Changing the screen phase!
Tum on I-1. PHASE switch and change the phase so that the screen may
come within the frame of marker with the encoder:
[Changing the centering(
Tum on 1-1. CENT switch for horizontal direction and tum on V. CENT
switch for vertical direction. Then change the centering so that the screen
phase may come to the center with the encoder.
[Changing the size(
Turn on 1-1. CENT switch for horizontal direction and tum on V. CENT
switch for vertical direction. Then change the centering so that the screen
phase may come to the center with the encodet:
[Changing the trapezoidal distortion(
Turn on EXPAND switch again and change the TRAPEZOID (trapezoidal
disto1tion) with the encodet:
I
Changing the side pin
I
When EXPAND switch is turned on again, SIDE PIN mode is selected.
Change SIDE PIN with the encoder.
(Entry of data
I
Alter completion of data change, press CHANGE PRESET switch to
r~gister changed data
[Clearing the data(
When CLEAR switch is pressed before registering data at the above-
mentioned Item 8, the data that was changed until this step is cleared,
returning to the former unchanged data.
I
Notes
J
Data ofI-1.PHASE, I-1.CEN-r, V.CENT, WIDTI-1, HEIGi-iT, TRAPEZOID and SIDE PIN is saved
as
individual data for every fotmat of each signal.
For WIDTH and HEIGHT, data for every SCAN size and aspect is saved. Therefore, when the following switching is performed during data
change, the data that is currently changed will be cleared. When changing other formats and SCAN size, regisger data beforehand.
Switch
of
input channel
SCAN switch
ASPECT switch
23