HTM-1505R/HTM-1505CS
16
[HTM-1505R model]
4.1 Power supply
G)
FUSE
/n,
Provided for overcun-ent protection.
:~}~ovQ-:::::1-----------:_ __
If_it_h_as_fi._1s_e_d_,
1_·e_p_ai_r_fa_u_lty_p_ru_t_ru_1_d_t1_1e_·n_i_n_se_rt_ra_te_d_4_A_(2_5_0_V_)_fu
s_e_. _________
~
CD
p~~~R
[D-----~--------i
Cg)
MAIN POWER Switch
When operating monitor. turn on this switch, and then turn on POWER switch on front pruiel.
Q)
AC POWER Input Connector
Insert attached AC cable here ru1d supply AC power to it.
@
Locking fixture
\\---;;i::;:::::;:;'.::==,!
1
....,.1--------f
To prevent coming off of AC plug, lock with this fixture utter inserting AC plug.
AC 100-120V
Fig. 4-1 Power unit on rear panel
4.2 Name and function of front left panel
□
Fig. 4-1 Front left panel
G)
Infrared sensor window
Infrared sensor window for
RCT-20A
wireless remote controlle1:
Cg)
NO BURST LED
Operates only when composite input signal is selected.
Lights up when no burst is added to selected composite signal (monochrome signal), or
when color-killer circuit is operated.
Q)
OVERLOAD
_Lights up when ABL circuit is operated (with brightness excessively increased).
When monitor is continuously used with this LED turned on for a long period of time,
CRT may degrade. Use with brightness lowered.
@
DEGAUSS Switch
To demagnetize CRT, turn it on.
(When power is turned on, monitor performs demagnetizing of CRT automatically.)
Pressing this switch continuously is inetlective.
To demagnetize sequentially, press this switch again alter lapse of2 to 3 minutes.
@
POWER Switch and LED
Used to turn ON/OFF power to monitor. LED is on when power supply is turned on.
When struting monitor, be sure to turn on MAIN POWER switch on rear pruiel.