Using Keypad in "Enable Keypad Only Operation" Mode

If the Enable Keypad Only Operation mode is activated, all users can either gain access by
presenting card or by entering their card number using the key. However, if the card(s) is set
in Card and PIN operation AND the door requires PIN code for entry, user(s) have to enter
their card number followed by their assigned PIN code before access is granted.
Manual Card Entry without PIN code
1.
2.
Follow the next set of procedures if PIN code is required.
Manual Card Entry with PIN code
1.
2.
3.
Reader's PIN code
When this mode is selected, all cardholders use a pre-determined Reader's PIN code to gain
access. No card is required. This setting is done in Card Readers, PIN Code Settings, Reader's
PIN code (1-7 digits). To gain access, enter the Reader's PIN code.
12.2.3

Other Usage

The following sections highlight the other usage of the Reader beside Door Access.
Time Clock Functions
Besides using the card for door access, it can be used for time clocking. For example, an
employee reports for work will be granted access to the building at the same time, the
employee can clock-in. These transactions are captured and presented in the Time Attendance
web page which can be exported in Comma Separated Variable (.csv) format and can be used
by third party payroll software. The function can also be used to capture the time, the guards
visited the checkpoint.
Notice!
No set-up is required in the AEC2.1 web page.
2018.11 | 1.0.6 | F.01U.122.796
Present the card to the Reader, the LED will flash at a slow rate for the duration as
depicted in the Reader's Keypad Time-out field.
Enter your PIN code. If the PIN code is valid, pull the door to get in. Otherwise, the LED
will flash at a fast rate, indicating a wrong PIN code.
First, press the key, The LED will flash continuously at a slow rate for the duration as
depicted in the Keypad Time-out field.
Key in your card number followed by the
door will be released momentarily for access. However, if the card number is not valid,
the LED will flash at a fast rate.
First, press the key, The LED will flash continuously at a slow rate for the duration as
depicted in the Keypad Time-out field.
Key in your card number followed by the
LED will flash at a medium rate. However, if the card number is not valid, the LED will
flash at a fast rate.
Enter the PIN code. If the PIN code is correct, the door will be released momentarily for
access. However, if the PIN code is wrong, the LED will flash at a fast rate.