Bosch Access Easy Controller 2.1 Hardware Installation Manual page 84

Table of Contents

Advertisement

84
en | How to Set Up the Access Easy Controller 2.1 and the Computer
4.
5.
6.
7.
8.
9.
The controller is now ready for connection to the customer's network. Usually, this connection
is made to a wall jack or hub using a straight-through network cable.
2018.11 | 1.0.6 | F.01U.122.796
Login to AEC2.1 using the user name "user1" and password "8088". Select the required
GUI language from the language dropdown. Click the Login button.
Result: Upon successful login, the AEC2.1 home page is displayed.
From the home page, select System > Network Settings.
Result: The Network Settings page displays.
Modify the Controller's IP Address, Subnet mask, and Gateway. Set these fields to the
values provided by the customer.
The values for these fields must be set correct for the controller to be able to operate
over the customer's network. The required settings must be obtained from the customer,
or a representative of the customer's Information Technology department.
After changing the settings, click the
From the home page, select System > Advance Configuration > System Maintenance >
Reboot to reboot the controller. This will cause the controller to reboot and load the new
IP address information that was entered and saved in the previous steps.
After rebooting, the controller will begin responding to its new address. It will no longer
respond to the default address 198.168.0.41.
Before connecting the controller to the customer's network, it is advisable to test it using
the new settings to confirm proper setup.
To do this, you will need to change the network configuration of your computer to an
address on the same network as the controller.
As an example, assume that in the previous steps you set the controller's address to
192.9.200.18 and the Subnet mask to 255.255.0.0. To test the controller using your
computer, the computer's network setup will need to be changed to a similar
address on the same network. For example, you could set the computer to
192.9.200.19. You should set the netmask on the computer to the same value as the
controller.
After changing network setup on the computer, the computer will need to be
rebooted. After rebooting connect the AEC2.1 by entering the new controller
address in the location or address bar of the browser.
If successful connection is made to the controller, the Login screen is displayed.
Once proper operation has been confirmed, Logout of the controller and close your
browser. Then disconnect the crossover cable from both the controller and the computer.
Hardware Installation Manual
save button to save the settings.
Access Easy Controller 2.1
Robert Bosch (SEA) Pte Ltd

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aec-aec21-ext1Apc-aec21-ups1

Table of Contents