en | Entry and Arm/Disarm Reader
17

Entry and Arm/Disarm Reader

AEC2.1 has the option to configure a reader as a normal door access reader and acts as an
Arming/Disarming reader at the same time. In order to achieve dual operation on the reader,
there are certain settings required.
The reader should be first configured as an Entry reader and must be set to an alarm zone to
arm/disarm the reader. Follow the steps below to set the reader as Entry and Arm/Disarm
reader:
1.
2.
3.
4.
5.
6.
7.
8.
2018.11 | 1.0.6 | F.01U.122.796
In the AEC2.1 software setup, select Configuration > Device > Door and click the
button to add new door settings. The screen below appears.
Enter a description for the reader in the Description field.
Select Entry Reader Only from the Door Model dropdown list.
Select an Alarm zone from the Arm/Disarm dropdown list, this will be the zone that the
reader will arm and disarm.
Select the Reader from the Entry Reader dropdown list.
Click the
save button to save the setting.
Click the IO Configuration tab to configure the IOs of the reader. The screen below
shows the IO Configuration page.
At this point you should configure all the settings related to the door access, such as
Door Strike Timer, Door Open Timer, Door Strike, etc
Hardware Installation Manual
Access Easy Controller 2.1