ABB ACH580 Series Installation, Operation And Maintenance Manual page 22

Hide thumbs Also See for ACH580 Series:
Table of Contents

Advertisement

22
UL (NEC) ratings at U
Output
Ratings
3-phase U
Power ratings are valid at nominal voltage, 460V.
UL (NEC) ratings at U
Output
Ratings
3-phase U
Power ratings are valid at nominal voltage, 460V.
ACH580-01 Installation
= 208 V
AC
N
Type
HP
= 460 V (380...415 V / 440...480 V)
N
1
ACH580-01-04A6-2
1.5
ACH580-01-06A6-2
2
ACH580-01-07A5-2
3
ACH580-01-10A6-2
5
ACH580-01-017A-2
7.5
ACH580-01-024A-2
10
ACH580-01-031A-2
15
ACH580-01-046A-2
20
ACH580-01-059A-2
25
ACH580-01-075A-2
30
ACH580-01-088A-2
40
ACH580-01-114A-2
50
ACH580-01-143A-2
60
ACH580-01-169A-2
75
ACH580-01-211A-2
100
ACH580-01-273A-2
= 460 V
AC
N
Type
HP
= 460 V (380...415 V / 440...480 V)
N
1
ACH580-01-02A1-4
1.5
ACH580-01-03A0-4
2
ACH580-01-03A5-4
3
ACH580-01-04A8-4
5
ACH580-01-07A6-4
7.5
ACH580-01-012A-4
10
ACH580-01-014A-4
15
ACH580-01-023A-4
20
ACH580-01-027A-4
25
ACH580-01-034A-4
30
ACH580-01-044A-4
40
ACH580-01-052A-4
50
ACH580-01-065A-4
60
ACH580-01-077A-4
75
ACH580-01-096A-4
ACH580 Installation, Operation and Maintenance Manual
Heat
Output ratings
dissipation
A
W
4.6
45
6.6
55
7.5
66
10.6
84
16.7
133
24.2
174
30.8
228
46.2
322
59.4
430
74.8
525
88
619
114
835
143
1035
169
1251
211
1521
273
2061
Heat
Output ratings
dissipation
A
W
2.1
45
3
55
3.5
66
4.8
84
7.6
133
12
174
14
228
23
322
27
430
34
525
44
619
52
835
65
1024
77
1024
96
1510
Air
Frame
flow
size
3
ft
/min
25
R1
25
R1
25
R1
25
R1
25
R1
59
R2
59
R2
105
R3
105
R3
170
R4
82
R5
82
R5
256
R6
265
R7
265
R7
324
R8
Air
Frame
flow
size
3
ft
/min
25
R1
25
R1
25
R1
25
R1
25
R1
25
R1
59
R2
59
R2
105
R3
105
R3
105
R3
79
R4
79
R4
79
R4
82
R5

Hide quick links:

Advertisement