GROUP 25
Speed control
25.01 Torque reference speed
control
25.02 Speed proportional gain
25.03 Speed integration time
25.04 Speed derivation time
25.05 Derivation filter time
25.06 Acc comp derivation time
25.07 Acc comp filter time
25.15 Proportional gain em stop
25.53 Torque prop reference
25.54 Torque integral reference
25.55 Torque deriv reference
25.56 Torque acc compensation
GROUP 28
Frequency reference chain
28.01 Frequency ref ramp input
28.02 Frequency ref ramp output
28.11 Ext1 frequency ref1
28.12 Ext1 frequency ref2
28.13 Ext1 frequency function
28.15 Ext2 frequency ref1
28.16 Ext2 frequency ref2
28.17 Ext2 frequency function
28.21 Constant frequency function
28.22 Constant frequency sel1
28.23 Constant frequency sel2
28.24 Constant frequency sel3
28.26 Constant frequency 1
28.27 Constant frequency 2
28.28 Constant frequency 3
28.29 Constant frequency 4
28.30 Constant frequency 5
28.31 Constant frequency 6
28.32 Constant frequency 7
28.41 Frequency ref safe
28.51 Critical frequency function
28.52 Critical frequency 1 low
28.53 Critical frequency 1 high
28.54 Critical frequency 2 low
28.55 Critical frequency 2 high
28.56 Critical frequency 3 low
28.57 Critical frequency 3 high
28.71 Freq ramp set selection
28.72 Freq acceleration time 1
28.73 Freq deceleration time 1
28.74 Freq acceleration time 2
28.75 Freq deceleration time 2
28.76 Freq ramp in zero source
28.92 Frequency ref act 3
28.96 Frequency ref act 7
28.97 Frequency ref unlimited
GROUP 30
Limits
30.01 Limit word 1
30.02 Torque limit status
30.11 Minimum speed
30.12 Maximum speed
30.13 Minimum frequency
30.14 Maximum frequency
30.17 Maximum current
30.18 Torq lim sel
30.19 Minimum torque 1
30.20 Maximum torque 1
30.21 Min torque 2 source
30.22 Max torque 2 source
30.23 Minimum torque 2
30.24 Maximum torque 2
30.26 Power motoring limit
30.27 Power generating limit
30.30 Overvoltage control
30.31 Undervoltage control
GROUP 31
Fault functions
31.01 External event 1 source
31.02 External event 1 type
31.03 External event 2 source
31.04 External event 2 type
31.05 External event 3 source
31.06 External event 3 type
31.07 External event 4 source
31.08 External event 4 type
31.09 External event 5 source
31.10 External event 5 type
31.11 Fault reset selection
31.12 Autoreset selection
31.13 Selectable fault
31.14 Number of trials
31.15 Total trials time
31.16 Delay time
31.19 Motor phase loss
ACH580-Parameter List
31.20 Earth fault
31.21 Supply phase loss
31.22 STO indication run/stop
31.23 Wiring or earth fault
31.24 Stall function
31.25 Stall current limit
31.26 Stall speed limit
31.27 Stall frequency limit
31.28 Stall time
31.30 Overspeed trip margin
31.32 Emergency ramp supervision
31.33 Emergency ramp supervision
delay
31.36 Aux fan fault bypass
GROUP 32
Supervision
32.01 Supervision status
32.05 Supervision 1 function
32.06 Supervision 1 action
32.07 Supervision 1 signal
32.08 Supervision 1 filter time
32.09 Supervision 1 low
32.10 Supervision 1 high
32.11 Supervision 1 hysteresis
32.15 Supervision 2 function
32.16 Supervision 2 action
32.17 Supervision 2 signal
32.18 Supervision 2 filter time
32.19 Supervision 2 low
32.20 Supervision 2 high
32.21 Supervision 2 hysteresis
32.25 Supervision 3 function
32.26 Supervision 3 action
32.27 Supervision 3 signal
32.28 Supervision 3 filter time
32.29 Supervision 3 low
32.30 Supervision 3 high
32.31 Supervision 3 hysteresis
32.35 Supervision 4 function
32.36 Supervision 4 action
32.37 Supervision 4 signal
32.38 Supervision 4 filter time
32.39 Supervision 4 low
32.40 Supervision 4 high
32.41 Supervision 4 hysteresis
32.45 Supervision 5 function
32.46 Supervision 5 action
32.47 Supervision 5 signal
32.48 Supervision 5 filter time
32.49 Supervision 5 low
32.50 Supervision 5 high
32.51 Supervision 5 hysteresis
32.55 Supervision 6 function
32.56 Supervision 6 action
32.57 Supervision 6 signal
32.58 Supervision 6 filter time
32.59 Supervision 6 low
32.60 Supervision 6 high
32.61 Supervision 6 hysteresis
GROUP 34
Timed functions
34.01 Timed functions status
34.02 Timer status
34.04 Season/exception day status
34.10 Timed functions enable
34.11 Timer 1 configuration
34.12 Timer 1 start time
34.13 Timer 1 duration
34.14 Timer 2 configuration
34.15 Timer 2 start time
34.16 Timer 2 duration
34.17 Timer 3 configuration
34.18 Timer 3 start time
34.19 Timer 3 duration
34.20 Timer 4 configuration
34.21 Timer 4 start time
34.22 Timer 4 duration
34.23 Timer 5 configuration
34.24 Timer 5 start time
34.25 Timer 5 duration
34.26 Timer 6 configuration
34.27 Timer 6 start time
34.28 Timer 6 duration
34.29 Timer 7 configuration
34.30 Timer 7 start time
34.31 Timer 7 duration
34.32 Timer 8 configuration
34.33 Timer 8 start time
34.34 Timer 8 duration
34.35 Timer 9 configuration
34.36 Timer 9 start time
34.37 Timer 9 duration
ACH580 Installation, Operation and Maintenance Manual
34.38 Timer 10 configuration
34.39 Timer 10 start time
34.40 Timer 10 duration
34.41 Timer 11 configuration
34.42 Timer 11 start time
34.43 Timer 11 duration
34.44 Timer 12 configuration
34.45 Timer 12 start time
34.46 Timer 12 duration
34.60 Season 1 start date
34.61 Season 2 start date
34.62 Season 3 start date
34.63 Season 4 start date
34.70 Number of active exceptions
34.71 Exception types
34.72 Exception 1 start
34.73 Exception 1 length
34.74 Exception 2 start
34.75 Exception 2 length
34.76 Exception 3 start
34.77 Exception 3 length
34.78 Exception day 4
34.79 Exception day 5
34.80 Exception day 6
34.81 Exception day 7
34.82 Exception day 8
34.83 Exception day 9
34.84 Exception day 10
34.85 Exception day 11
34.86 Exception day 12
34.87 Exception day 13
34.88 Exception day 14
34.89 Exception day 15
34.90 Exception day 16
34.100 Timed function 1
34.101 Timed function 2
34.102 Timed function 3
34.110 Boost time function
34.111 Boost time activation source
34.111 Boost time duration
GROUP 35
Motor thermal protection
35.01 Motor estimated temperature
35.02 Measured temperature 1
35.03 Measured temperature 2
35.11 Temperature 1 source
35.12 Temperature 1 fault limit
35.13 Temperature 1 warning limit
35.14 Temperature 1 AI source
35.21 Temperature 2 source
35.22 Temperature 2 fault limit
35.23 Temperature 2 warning limit
35.24 Temperature 2 AI source
35.31 Safe motor temperature
enable
35.50 Motor ambient temperature
35.51 Motor load curve
35.52 Zero speed load
35.53 Break point
35.54 Motor nominal temperature
rise
35.55 Motor thermal time constant
GROUP 36
Load analyzer
36.01 PVL signal source
36.02 PVL filter time
36.06 AL2 signal source
36.07 AL2 signal scaling
36.09 Reset loggers
36.10 PVL peak value
36.11 PVL peak date
36.12 PVL peak time
36.13 PVL current at peak
36.14 PVL DC voltage at peak
36.15 PVL speed at peak
36.16 PVL reset date
36.17 PVL reset time
36.20 AL1 0 to 10%
36.21 AL1 10 to 20%
36.22 AL1 20 to 30%
36.23 AL1 30 to 40%
36.24 AL1 40 to 50%
36.25 AL1 50 to 60%
36.26 AL1 60 to 70%
36.27 AL1 70 to 80%
36.28 AL1 80 to 90%
36.29 AL1 over 90%
36.40 AL2 0 to 10%
36.41 AL2 10 to 20%
36.42 AL2 20 to 30%
36.43 AL2 30 to 40%
36.44 AL2 40 to 50%
36.45 AL2 50 to 60%
36.46 AL2 60 to 70%
36.47 AL2 70 to 80%
36.48 AL2 80 to 90%
36.49 AL2 over 90%
36.50 AL2 reset date
36.51 AL2 reset time
GROUP 37
User load curve
37.01 ULC output status word
37.02 ULC supervision signal
37.03 ULC overload actions
37.04 ULC underload actions
37.11 ULC speed table point 1
37.12 ULC speed table point 2
37.13 ULC speed table point 3
37.14 ULC speed table point 4
37.15 ULC speed table point 5
37.16 ULC frequency table point 1
37.17 ULC frequency table point 2
37.18 ULC frequency table point 3
37.19 ULC frequency table point 4
37.20 ULC frequency table point 5
37.21 ULC underload point 1
37.22 ULC underload point 2
37.23 ULC underload point 3
37.24 ULC underload point 4
37.25 ULC underload point 5
37.31 ULC overload point 1
37.32 ULC overload point 2
37.33 ULC overload point 3
37.34 ULC overload point 4
37.35 ULC overload point 5
37.41 ULC overload timer
37.42 ULC underload timer
GROUP 40
Process PID set 1
40.01 Process PID output actual
40.02 Process PID feedback
actual
40.03 Process PID setpoint actual
40.04 Process PID deviation actual
40.06 Process PID status word
40.07 Process PID operation mode
40.08 Set 1 feedback 1 source
40.09 Set 1 feedback 2 source
40.10 Set 1 feedback function
40.11 Set 1 feedback filter time
40.14 Set 1 setpoint scaling
40.15 Set 1 output scaling
40.16 Set 1 setpoint 1 source
40.17 Set 1 setpoint 2 source
40.18 Set 1 setpoint function
40.19 Set 1 internal setpoint sel1
40.20 Set 1 internal setpoint sel2
40.21 Set 1 internal setpoint 1
40.22 Set 1 internal setpoint 2
40.23 Set 1 internal setpoint 3
40.24 Set 1 internal setpoint 0
40.26 Set 1 setpoint min
40.27 Set 1 setpoint max
40.28 Set 1 setpoint increase time
40.29 Set 1 setpoint decrease time
40.30 Set 1 setpoint freeze enable
40.31 Set 1 deviation inversion
40.32 Set 1 gain
40.33 Set 1 integration time
40.34 Set 1 derivation time
40.35 Set 1 derivation filter time
40.36 Set 1 output min
40.37 Set 1 output max
40.38 Set 1 output freeze enable
40.39 Set 1 deadband range
40.40 Set 1 deadband delay
40.43 Set 1 sleep level
40.44 Set 1 sleep delay
40.45 Set 1 sleep boost time
40.46 Set 1 sleep boost step
40.47 Set 1 wake-up deviation
40.48 Set 1 wake-up delay
40.49 Set 1 tracking mode
40.50 Set 1 tracking ref selection
40.57 PID set1/set2 selection
40.58 Set 1 increase prevention
40.59 Set 1 decrease prevention
40.60 Set 1 PID activation source
40.61 Setpoint scaling actual
40.62 PID internal setpoint actual
40.70 Compensated setpoint
40.71 Set 1 compensation input
source
40.72 Set 1 compensation input 1

Hide quick links: