154
71.34 Derivation time
71.35 Derivation filter time
71.36 Output min
71.37 Output max
71.38 Output freeze enable
71.39 Deadband range
71.40 Deadband delay
71.58 Increase prevention
71.59 Decrease prevention
71.62 Internal setpoint actual
GROUP 72
External PID2
72.01 External PID act value
72.02 Feedback act value
72.03 Setpoint act value
72.04 Deviation act value
72.06 PID status word
72.07 PID operation mode
72.08 Feedback 1 source
72.11 Feedback filter time
72.14 Setpoint scaling
72.15 Output scaling
72.16 Setpoint 1 source
72.19 Internal setpoint sel1
72.20 Internal setpoint sel2
72.21 Internal setpoint 1
72.22 Internal setpoint 2
72.23 Internal setpoint 3
72.26 Setpoint min
72.27 Setpoint max
72.31 Deviation inversion
72.32 Gain
72.33 Integration time
72.34 Derivation time
72.35 Derivation filter time
72.36 Output min
72.37 Output max
72.38 Output freeze enable
72.39 Deadband range
72.40 Deadband delay
72.58 Increase prevention
72.59 Decrease prevention
72.62 Internal setpoint actual
GROUP 73
External PID3
73.01 External PID act value
73.02 Feedback act value
73.03 Setpoint act value
73.04 Deviation act value
73.06 PID status word
73.07 PID operation mode
73.08 Feedback 1 source
73.11 Feedback filter time
73.14 Setpoint scaling
73.15 Output scaling
73.16 Setpoint 1 source
73.19 Internal setpoint sel1
73.20 Internal setpoint sel2
73.21 Internal setpoint 1
73.22 Internal setpoint 2
73.23 Internal setpoint 3
73.26 Setpoint min
73.27 Setpoint max
73.31 Deviation inversion
73.32 Gain
73.33 Integration time
73.34 Derivation time
73.35 Derivation filter time
73.36 Output min
73.37 Output max
73.38 Output freeze enable
73.39 Deadband range
73.40 Deadband delay
73.58 Increase prevention
73.59 Decrease prevention
73.62 Internal setpoint actual
GROUP 74
External PID4
74.01 External PID act value
74.02 Feedback act value
74.03 Setpoint act value
74.04 Deviation act value
74.06 PID status word
74.07 PID operation mode
74.08 Feedback 1 source
74.11 Feedback filter time
74.14 Setpoint scaling
74.15 Output scaling
74.16 Setpoint 1 source
74.19 Internal setpoint sel1
74.20 Internal setpoint sel2
74.21 Internal setpoint 1
ACH580-Parameter List
74.22 Internal setpoint 2
74.23 Internal setpoint 3
74.26 Setpoint min
74.27 Setpoint max
74.31 Deviation inversion
74.32 Gain
74.33 Integration time
74.34 Derivation time
74.35 Derivation filter time
74.36 Output min
74.37 Output max
74.38 Output freeze enable
74.39 Deadband range
74.40 Deadband delay
74.58 Increase prevention
74.59 Decrease prevention
74.62 Internal setpoint actual
GROUP 76
PFC configuration
76.01 PFC status
76.02 Multipump system status
76.11 Pump/fan status 1
76.12 Pump/fan status 2
76.13 Pump/fan status 3
76.14 Pump/fan status 4
76.21 Multipump configuration
76.25 Number of motors
76.26 Min number of motors
allowed
76.27 Max number of motors
allowed
76.30 Start point 1
76.31 Start point 2
76.32 Start point 3
76.41 Stop point 1
76.42 Stop point 2
76.43 Stop point 3
76.55 Start delay
76.56 Stop delay
76.57 PFC speed hold on
76.58 PFC speed hold off
76.59 PFC contactor delay
76.60 PFC ramp acceleration time
76.61 PFC ramp deceleration time
76.70 Autochange
76.71 Autochange interval
76.72 Maximum wear imbalance
76.73 Autochange level
76.74 Autochange auxiliary PFC
76.81 PFC 1 interlock
76.82 PFC 2 interlock
76.83 PFC 3 interlock
76.84 PFC 4 interlock
76.95 Regulator bypass control
GROUP 77
PFC maintenance and monitoring
77.10 PFC runtime change
77.11 Pump/fan 1 running time
77.12 Pump/fan 2 running time
77.13 Pump/fan 3 running time
77.14 Pump/fan 4 running time
GROUP 80
Flow calculation
80.01 Actual flow
80.02 Actual flow percentage
80.11 Flow feedback 1 source
80.12 Flow feedback 2 source
80.13 Flow feedback function
80.14 Flow feedback multiplier
80.15 Maximum flow
80.16 Motor cos ɸ
GROUP 95
HW configuration
95.01 Supply voltage
95.02 Adaptive voltage limits
95.03 Estimated AC supply voltage
95.04 Control board supply
95.15 Special HW settings
95.20 HW options word 1
95.21 HW options word 2
GROUP 96
System
96.01 Language
96.02 Pass code
96.03 Access level status
96.04 Macro select
96.05 Macro active
96.06 Parameter restore
96.07 Parameter save manually
96.08 Control board boot
96.10 User set status
ACH580 Installation, Operation and Maintenance Manual
96.11 User set save/load
96.12 User set I/O mode in1
96.13 User set I/O mode in2
96.16 Unit selection
96.20 Time sync primary source
96.51 Clear fault and event logger
96.70 Disable adaptive program
GROUP 97
Motor control
97.01 Switching frequency
reference
97.02 Minimum switching
frequency
97.03 Slip gain
97.04 Voltage reserve
97.05 Flux braking
97.08 Optimizer minimum torque
97.09 Switching frequency mode
97.10 Signal injection
97.11 TR tuning
97.13 IR compensation
97.15 Motor model temperature
adaptation
97.16 Stator temperature factor
97.17 Rotor temperature factor
97.20 U/F Ratio
GROUP 98
User motor parameters
98.01 User motor model mode
98.02 Rs user
98.03 Rr user
98.04 Lm user
98.05 SigmaL user
98.06 Ld user
98.07 Lq user
98.08 PM flux user
98.09 Rs user SI
98.10 Rr user SI
98.11 Lm user SI
98.12 SigmaL user SI
98.13 Ld user SI
98.14 Lq user SI
GROUP 99
Motor data
99.03 Motor type
99.04 Motor control mode
99.06 Motor nominal current
99.07 Motor nominal voltage
99.08 Motor nominal frequency
99.09 Motor nominal speed
99.10 Motor nominal power
99.11 Motor nominal cos ɸ
99.12 Motor nominal torque
99.13 ID run requested
99.14 Last ID run performed
99.15 Motor polepairs calculated
99.16 Motor phase order