Mitsubishi Electric FR-S520E Series Instruction Manual page 44

Transistored inverter
Table of Contents

Advertisement

Input terminals
Terminal Input
REX-
RH-
Speed
SD*
SD
Speed 1
(high
OFF
ON
speed)
Speed 2
(middle
OFF OFF
speed)
Speed 3
(low
OFF OFF OFF
speed)
Speed 4 OFF OFF
Speed 5 OFF
ON
Speed 6 OFF
ON
Speed 7 OFF
ON
Speed 8
OFF OFF OFF
ON
Speed 9
OFF OFF
ON
Speed 10
OFF
ON
Speed 11
OFF
ON
Speed 12
ON
ON
Speed 13
ON
ON
Speed 14
ON
ON
Speed 15
ON
ON
External
OFF OFF OFF OFF
setting
*When using the REX signal, an external command cannot be used to make a
reverse rotation start.
Power supply
REMARKS
*1. When the frequency setting potentiometer is connected, the input signal of the frequency
setting potentiometer is ignored if the multi-speed select signal is switched on. (This also
applies to the 4 to 20mA input signal.)
*2. For a reverse rotation start, set Pr. 63 to "- - -" (factory setting) to make the STR signal of
terminal STR valid.
Multi-Speed Setting
RM-
RL-
Parameter
SD
SD*
OFF OFF
Pr. 4
OFF
Pr. 5
ON
Pr. 6
ON
Pr. 24
ON
ON
OFF
Pr. 25
ON
OFF
Pr. 26
ON
Pr. 27
ON
ON
Pr. 80
Pr. 81
ON
OFF
Pr. 82
ON
Pr. 83
ON
ON
OFF OFF
Pr. 84
OFF
Pr. 85
ON
OFF
Pr. 86
ON
Pr. 87
ON
ON
Frequency
setting
potentiometer
Forward rotation
Multi-speed
selection
Multi-Speed Operation Connection Example
Set Frequency
Range
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz, - - -
0 to max. setting
R
U
S
V
T
W
Inverter
STF
*2
REX
10
RH
Frequency
2
RM
setting
5
potentiometer
RL
SD
34
Remarks
⎯⎯⎯⎯⎯⎯⎯
⎯⎯⎯⎯⎯⎯⎯
⎯⎯⎯⎯⎯⎯⎯
Pr. 6 setting when Pr. 24="- - -"
Pr. 6 setting when Pr. 25="- - -"
Pr. 5 setting when Pr. 26="- - -"
Pr. 6 setting when Pr. 27="- - -"
0Hz when Pr. 80="- - -"
Pr. 6 setting when Pr. 81="- - -"
Pr. 5 setting when Pr. 82="- - -"
Pr. 6 setting when Pr. 83="- - -"
Pr. 4 setting when Pr. 84="- - -"
Pr. 6 setting when Pr. 85="- - -"
Pr. 5 setting when Pr. 86="- - -"
Pr. 6 setting when Pr. 87="- - -"
⎯⎯⎯⎯⎯⎯⎯
IM
Motor
*1