Terminal function selection
2.9.2
Output terminal function selection (Pr. 64
You can change the functions of the open collector output terminal and contact
output terminal.
Parameter
RUN terminal function
64
selection
A, B, C terminal function
65
selection
<Setting>
Signal
Setting
Name
0
RUN
1
SU
3
OL
4
FU
11
RY
12
Y12
13
Y13
14
FDN
15
FUP
16
RL
93
Y93
95
Y95
98
LF
99
ABC
REMARKS
One function can be assigned to two terminals.
Name
Function
Inverter running
Up to frequency
Overload alarm
Output frequency
detection
Inverter operation
ready
Output current
detection
Zero current detection
PID lower limit
PID upper limit
PID forward-reverse
rotation output
Current average value
monitor signal
Maintenance timer
alarm
Minor fault output
Alarm output
Factory
Setting Range
Setting
0, 1, 3, 4, 11 to
0
16, 93, 95, 98, 99 Setting is enabled
0, 1, 3, 4, 11 to
99
16, 95, 98, 99
Operation
Output during operation when the
inverter output frequency rises to
or above the starting frequency.
Output when the output frequency
is reached.
Output while stall prevention
function is activated.
Output when the output frequency
rises to or above the setting.
Output when the inverter is ready
to be started by switching the
start signal on.
Output when the output current
rises to or above the setting.
Output when the output current
reaches 0.
Outputs the detection signal
under PID control.
The output current average value
and maintenance timer value are
output during the constant speed
operation. (can be set to the RUN
terminal (Pr.64) only)
Output when additional
parameter H1 is greater than
maintenance parameter H2.
Output when a minor fault (fan
failure or communication error
warning) occurs.
Output when the inverter's
protective function is activated to
stop the output (major fault).
110
, Pr. 65
Remarks
when Pr. 30 = "1"
Parameters
Referred to
Pr. 2, Pr. 13
Pr. 41
Pr. 21, Pr. 22,
Pr. 23, Pr. 28
Pr. 42, Pr. 43
Pr. 48, Pr. 49
Pr. 50, Pr. 51
Pr. 88 to Pr. 94
H3 to H5
H1, H2
Pr. 76, n5
)