Acceleration/Deceleration Time (Pr. 7 , Pr. 8 , Pr. 20 , Pr. 44 , Pr. 45 ) - Mitsubishi Electric FR-S520E Series Instruction Manual

Transistored inverter
Table of Contents

Advertisement

Explanation of functions (parameters)
CAUTION
1. The multi-speed settings override the main speeds (across terminals 2-5, 4-
5, setting dial). When the multi-speed settings and setting dial are used in
the combined operation mode (Pr. 79 = 3), the multi-speed settings have
precedence.
2. The multi-speeds can also be set in the PU or external operation mode.
3. For 3-speed setting, if two or three speeds are simultaneously selected,
priority is given to the set frequency of the lower signal.
4. Pr. 24 to Pr. 27 and Pr. 80 to Pr. 87 settings have no priority between them.
5. The parameter values can be changed during operation.
6. When using this function with the jog signal, the jog signal has precedence.
REMARKS
The frequency-set external terminals have the following priority:
Jog > multi-speed operation > AU (terminal 4) > terminal 2
♦Related parameters♦
Maximum, minimum frequency setting ⇒ Pr. 1 "maximum frequency", Pr. 2 "minimum frequency"
Assignment of signals RH, RM, RL, REX to terminals ⇒ Pr. 60 to Pr. 63 (input terminal function
External operation mode setting ⇒ Pr. 79 "operation mode selection" (refer to page 119)
Computer link mode ⇒ Pr. 79 "operation mode selection" (refer to page 119), communication
Speed command source ⇒ Communication parameter n9 "speed command source"
2.3.5
Acceleration/deceleration time (Pr. 7
Pr. 20
Used to set motor acceleration/
deceleration time.
Set a larger value for a slower
speed increase/decrease or a
smaller value for a faster speed
increase/decrease.
Parameter
7
Acceleration time
8
Deceleration time
Acceleration/
20
deceleration reference
frequency
Second acceleration/
44
deceleration time
Second deceleration
45
time
parameter n10 "link startup mode selection" (refer to page 161)
(refer to page 160)
, Pr. 44
Factory
Name
Setting
5s
5s
60Hz
5s
- - -
(refer to page 72)
selection) (refer to page 108)
, Pr. 45
Pr.20
Pr.7
Pr.44
Acceleration
Setting
Range
0 to 999s
0 to 999s
Setting is enabled when
1 to 120Hz
Pr. 30 = "1".
Setting is enabled when
0 to 999s
Pr. 30 = "1".
- - -:
0 to 999s,
acceleration time=
- - -
deceleration time.
76
, Pr. 8
)
Constant speed
Acceleration
Deceleration
Deceleration
time
time
Remarks
----------
----------
Setting is
enabled when
Pr. 30 = "1".
,
Running
frequency
Time
Pr.8
Pr.45