Mitsubishi Electric FR-S520E Series Instruction Manual page 78

Transistored inverter
Table of Contents

Advertisement

Function (Parameter) list
Calibration parameters
Func-
Parame-
Indi-
tion
ters
cation
C1 (900)
C2 (902)
C3 (902)
C4 (903)
C5 (904)
C6 (904)
C7 (905)
C8 (269)
CLr
ECL
* Factory settings may differ because of calibration parameters.
REMARKS
1. The parameter number in parentheses is the one for use with the parameter unit (FR-PU04).
2. Set "9999" when setting a value "- - -" using the parameter unit (FR-PU04).
3. The decimal places of a value 100 or more (3 digits or more) cannot be displayed.
Name
Setting Range
FM terminal
calibration
Frequency
setting voltage
0 to 60Hz
bias frequency
Frequency setting
0 to 300%
voltage bias
Frequency setting
0 to 300%
voltage gain
Frequency
setting current
0 to 60Hz
bias frequency
Frequency setting
0 to 300%
current bias
Frequency setting
0 to 300%
current gain
Parameter for manufacturer setting. Do not set.
0: Not executed
Parameter clear
1: Parameter clear
10: All clear
0: Not cleared,
Alarm history
1: Alarm history
clear
Minimum
Setting
Incre-
ments
⎯⎯
⎯⎯
0.1Hz
0.1%
0.1%
0.1Hz
0.1%
0.1%
clear
68
Factory
Refer
Setting
To:
⎯⎯
138
0Hz
91
0% (*)
91
96%
91
(*)
0Hz
91
20% (*)
91
100%
91
(*)
1
0
141
1
0
141
Cus-
tomer
Setting