FLIR BLACKFLY S USB Vision Installation Manual page 26

Table of Contents

Advertisement

Diagram
Color
Green
Black
Red
White
Blue
Brown
Measurement conditions: Opto-Isolated I/O VCC=5V, Rext=1KOhm, Non-Isolated Output: VCC=5V, Rext=330 Ohm, Non-Isolated Input:
VCC=3.3V. Measured over operating temperature range (-20˚C to +50˚C ambient temperature), unless otherwise noted.
1—GPIO cable assembly wire colors
2—Dual function pin
3—Open drain output, requires pullup resistor
4—Output low level depends on the output voltage / pullup resistor combination
5/4/2017
©2015-2017 FLIR
Integrated Imaging
Solutions Inc.
All rights reserved.
1
Pin Line
Function
V
AUX
2
1
3
GPI
2
0
OPTOIN
VOUT
2
3
2
3
GPIO
OPTOOUT
4
1
3
5
N/A Opto GND
6
N/A
GND
FLIR Blackfly
6 Blackfly S Physical Interface
Description
Parameter
Auxiliary
Input Voltage
Input Voltage Range
(DC)
Input Low Level
Non-isolated
Input High Level
Input
Propagation Delay
Input Low Level
Input High Level
Input Current
Opto-isolated
Propagation Delay
Input
Low to High
Propagation Delay
High to Low
Camera
Output Voltage
Power
Output Current
Output
Input Low Level
Input High Level
Non-isolated
Propagation Delay
Input/Ouput
Output Low Current
Output High Level
Output Low Current
Output High Level
Opto-isolated
Propagation Delay
Output
Low to High
Propagation Delay
High to Low
Opto-isolated
Ground
Camera
Power
Ground
®
S Installation Guide
Min Max Unit
8
24
V
0
1.4
V
2.6
3.6
V
1
μs
0
1.4
V
2.6
30
V
3.5
7
mA
18
μs
9
μs
3.05 3.35
V
120
mA
0
1.4
V
2.6
24
V
1
μs
25
mA
0
24
V
4
25
mA
0
24
V
36
μs
18
μs