COMPONENT ACCESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
To Remove the RFI Filter
1. Unplug washer or disconnect power.
2. Turn off water supply to washer.
3. Disconnect cold inlet water hose and remove the drain
hose from the standpipe or laundry tub.
4. Perform the procedures on page 4-3, "Removing the Top
Panel" prior to performing the following steps.
5. Using a Phillips screwdriver, remove the three (3) screws
indicated in Figure 1. Remove terminal box cover.
Remove 3 Screws
6. Inside the terminal box, remove the four (4) Phillips
screws securing the terminal box to the rear panel (circled
in Figure 2).
4-14
Whirlpool Smart All-In-One Washer & Dryer
n
Removing the RFI Filter
Figure 1
7. If a 4-Wire power cord is connected, use an 8 mm driver
to remove the grounding screw and ground wire (see
Figure 2). Gently, pull the terminal box away from the rear
panel.
8. Remove the Phillip screw and slide the RFI Filter to the left
to disengage from rear panel (see Figure 3).
Remove 1
Screw
Slide filter to remove
9. Disconnect the RFI's Filter's L1 and L2 terminals, and
output connector to ACU (see Figure 4).
RFI Output to ACU
Brown: L1, Blue: L2
10. Reverse procedure to reinstall the RFI Filter.
Ground Wire
Screw
Figure 2
Figure 3
L1
L2
Figure 4