 3. CONTROLLER INSTALLATION
 

27V SMPSU MODULE

 
The controller includes a 27V/150W (5.6A) switched mode power supply unit with solid state overload protection. With the 
mains supply ON the green output healthy LED should be illuminated. The output voltage is factory set to 27.5V DC (with 
the batteries disconnected) using a DVM across V+/V‐. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

BATTERY STANDBY

 
In the event of a mains failure, two 12V 5Ah rechargeable batteries will maintain a typical  
system for approx. 8 hours. A protection circuit will disconnect the battery supply in the  
event of prolonged mains failure to prevent damage to the batteries. The mains supply  
must be applied first to energise the protection circuit, i.e. the system will not function  
by simply connecting the batteries alone. 
 

TELEPHONE CONNECTION

 
Two BT master sockets (not supplied) are required to connect the external telephone line and the local DECT base 
stations/fixed CLI telephones to the controller.  
 
 
 
 
 
 
 
 
 
 
 
 
 
PSTN
LINE
 
 
 
 
DECT
 
 
 
 
 
 
 
The PSTN line should be terminated in a master socket by the telephone company. Connect a 2 pair CW1308 spec cable 
from the second master socket (terminals 2, 3 & 5) to the DECT base station, Matrix IP PBX or fixed telephone sockets on 
the scheme. Note a maximum of 4 devices can be connected to the Advent xt. 
 
 
 
 
 
 
 
 
Doc No. FM0410 issue M‐1 Page 7
 
27V/150W SMPSU 
TERMINATION
BOARD
BATTERY
BATTERY
SMPSU
MODULE
(W00581) 
27V OUTPUT HEALTHY LED 
2 x MASTER
BT SOCKETS
BT LEADS
SUPPLIED
MAINS LIVE 
MAINS NEUTRAL 
MAINS EARTH 
0V 
0V 
27.5VDC 
27.5VDC 
27V ADJUST 
BT LINE
IN
TO DECT
BASE
STATIONS