Kirk 6500 Configuration - Tynetec Advent xt Installation Manual

Warden call system
Hide thumbs Also See for Advent xt:
Table of Contents

Advertisement

 34. KIRK 6500 DECT 
 
If full site coverage cannot be achieved using the Kirk 400 multi cell option then the Kirk 6500 must be used. 
The standard Kirk 6500 can expand up to 8 base stations, 24 repeaters and 64 DECT telephones, larger systems are possible 
by adding additional Fastswitch's to increase the number of PoE Ports, contact Tynetec's customer support for advice. 

KIRK 6500 CONFIGURATION

700VA 
  UPS 
 External Tel Line 
Advent xt Line 
 
 
 
 
 
 
 
Desk CLI  
   Telephone 
 
PART NUMBERS
 
Part No. 
 
ZXT548 
ZXT556 
ZXT549 
ZXT535 
ZXT536 
ZXT544 
ZXT523 
ZXT524 
ZCS729 
W00525 
F00040 
 
  
Note: the Kirk 6500 Wireless Server allows connection of 256 radio points 
 
POWER CONNECTION
  
To maintain DECT operation during a mains failure the Matrix, Fastswitch and Kirk 6500 Wireless Server must all be 
powered from the 700VA UPS, the Repeaters must be powered from a battery backed 12V DC power supply.  
 
If the Matrix, Fastswitch and Wireless Server are plugged directly into the mains and Repeaters are powered via in‐line PSU 
modules there will be no DECT coverage during a mains failure; however the fixed CLI desk telephone will still operate. 
 
 
 
Doc No. FM0410 issue M‐1 Page 55
 
16 Port Fastswitch 
                      (8 x PoE)
240V 
 AC  
Kirk 6500 Wireless 
 Server (1 only)
Matrix  
     IP PBX 
See Tynetec Drg No. ZXT100 issue L sheet 9 for detailed connections 
Description 
 
700VA UPS 
Matrix Eternity IP PBX 
16 Port Fastswitch (8 x PoE) 
Kirk 6500 Wireless Server 
IP 12 Channel Base Station
4 Channel Multi Cell Repeater
Spectralink 7202 DECT Phone & Charger 
Spectralink 7212 DECT Phone & Charger 
Kirk Repeater Programming Kit 
12V 2A Boxed PSU 
12V 3.4Ah Rechargeable Battery 
which can be made up of either Base Stations or Repeaters. 
  DECT Telephones (64 standard) 
 IP 12 Channel Base Stations (8 standard) 
Repeaters (max 3 per Base Station = 24 standard)
12V DC PSU
 
240V
  AC  
 
 
 
Notes 
 
1 per site 
1 per site 
As required 
1 per site 
 
max 8 per Fastswitch (8 x PoE) 
 
max 3 per IP Base Station 
max 64 per site (4096 with 
additional licences) 
1 off purchase 
1 per 6 Repeaters 
1 per PSU 
4 Channel Multi Cell Repeaters 