 9. INTERCOM UNIT INSTALLATION
 
The intercom unit should be wall mounted in a central location within each dwelling. Screw fix the intercom rear securely 
to the wall using the 4 holes marked "A". The 2 holes marked "B" can be used for an embedded box. Ensure the case is not 
twisted as this may prevent the lid fitting correctly.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The network cable should loop‐in and out of each intercom via the cable entry channel on the top or the square cut‐out in 
the rear. Wherever possible avoid cable entry from below as this may interfere with the operation of the emergency 
pullcord. The cable clips marked "C" can be used to retain spare cores and prevent possible short circuits when the 
intercom front is fitted. 
 

INTERCOM TERMINATION

 
The network wiring is terminated on the interconnect board in the rear section of the intercom as shown below;  
 
 
 
 
 
NETWORK  
 

     WIRING  
               IN  
 
 
 
 
 
 
 
 
 
 
 
 
 
The 12V connection (COM) is only necessary if there are auxiliary devices within the dwelling that require a 12V DC supply. 
Likewise, the PA1/PA2 connection is only necessary for the public address option or if door entry telephones are fitted.  
If all cores are available in the network cable it is good practice to make all the connections for possible future upgrades. 
 
 
 
 
 
 
 
 
 
 
 
Doc No. FM0410 issue M‐1 Page 15
 
 
 
 
FIXING HOLES 
 
 
 
"B" ON 60mm 
 
 
 
 
 
 
 
 
 
CABLE ENTRY
 
 
A
CABLE
 
 
 
B
ENTRY
CENTRES 
C
A00399
A
 
 
    70mm 
 
 
 
 
 
 
Intercom 
11 
12 
COM 
A
 
 
97mm 
B
C
A
 
 
       NETWORK 
  WIRING 
 
                           OUT 
Network 
24V DC 
0V 
TX+ 
TX‐ 
SP1 
SP2 
MIC 
PA1 
PA2 
12V DC 