9. INTERCOM UNIT INSTALLATION
The intercom unit should be wall mounted in a central location within each dwelling. Screw fix the intercom rear securely
to the wall using the 4 holes marked "A". The 2 holes marked "B" can be used for an embedded box. Ensure the case is not
twisted as this may prevent the lid fitting correctly.
The network cable should loop‐in and out of each intercom via the cable entry channel on the top or the square cut‐out in
the rear. Wherever possible avoid cable entry from below as this may interfere with the operation of the emergency
pullcord. The cable clips marked "C" can be used to retain spare cores and prevent possible short circuits when the
intercom front is fitted.
INTERCOM TERMINATION
The network wiring is terminated on the interconnect board in the rear section of the intercom as shown below;
NETWORK
WIRING
IN
The 12V connection (COM) is only necessary if there are auxiliary devices within the dwelling that require a 12V DC supply.
Likewise, the PA1/PA2 connection is only necessary for the public address option or if door entry telephones are fitted.
If all cores are available in the network cable it is good practice to make all the connections for possible future upgrades.
Doc No. FM0410 issue M‐1 Page 15
FIXING HOLES
"B" ON 60mm
CABLE ENTRY
A
CABLE
B
ENTRY
CENTRES
C
A00399
A
70mm
Intercom
1
2
3
4
5
6
7
11
12
COM
A
97mm
B
C
A
NETWORK
WIRING
OUT
Network
24V DC
0V
TX+
TX‐
SP1
SP2
MIC
PA1
PA2
12V DC