 31. KIRK 400 SOLO BASE DECT ‐ REPEATER DEPLOYMENT
 

REPEATER DEPLOYMENT RULES

 
A maximum of 6 Repeaters can be configured on a Kirk 400 Solo Base Wireless Server (KWS400) RPN 3 
A maximum of 3 Repeaters can be configured in a chain 
If you have up to 3 Repeaters they should be numbered: 67, 131 and 195 i.e. RPN 3 +64, +128 and +192 
If you have more than 3 Repeaters they should be assigned one of the following: 35, 67, 99, 131, 163, 195 & 227  
2 Repeaters cannot have the same number 
See deployment examples below; RPN = the Radio Part Number 
 
KWS400 is shaded RED          Repeaters are shaded GREEN         Radio handover BLUE         
 
 
 
 
Solo Base 
 
RPN 3 
 
 
1 REPEATER DEPLOYMENT
 
1 Repeater connected directly: 
 
 
 
 
 
 
 
Solo Base 
 
RPN 3 
 
2 REPEATER DEPLOYMENT EXAMPLES
 
2 Repeaters connected directly: 
 
 
 
 
 
 
 
Repeater 
 
RPN 67 
 
2 Repeaters connected in a chain: 
 
 
 
 
 
 
 
Solo Base 
 
RPN 3 
 
3 REPEATER DEPLOYMENT EXAMPLES
 
3 Repeaters connected in a chain: 
 
 
 
 
 
 
 
Solo Base 
 
RPN 3 
 
1 Repeater connected directly and 2 in a chain: 
 
 
 
 
 
 
 
Repeater 
 
RPN 67 
 
 
 
 
 
Doc No. FM0410 issue M‐1 Page 47
Repeater 
RPN XX
Repeater 
RPN 67 
Solo Base 
Repeater 
RPN 3 
RPN 131
Repeater 
Repeater 
RPN 67 
RPN 131
Repeater 
Repeater 
RPN 67 
RPN 131
Solo Base 
Repeater 
RPN 3 
RPN 131
 
Repeater 
RPN 195
Repeater 
RPN 195