 14. INTERCOM UNIT TEST MODE
 
The intercom unit Test Mode allows all input devices to be tested on a per‐flat basis without putting a call on the system. 
Once in Test Mode the intercom will beep as each device is activated, the system printer will log each test with the flat 
number, device type, time and date.  
 
The intercom must be in a quiescent state to enter the Test Mode, i.e. not in privacy mode, no message waiting, no alarm 
call in progress and not awaiting Extracare cancellation.  
 
 
 
 
 
 
 
 
         
       
 
 
 
 
 
 
 
 
 
 
 
       
 
 
 
 
 

TO ENTER TEST MODE

 
 
Press and hold the       
 button for about 5 seconds until the intercom beeps once ‐ then release within 2 seconds or the 
 
Test Mode will not be enabled. 
 
When the intercom is in test mode the white LED will flash and a 7 tone ascending scale will play once. 
 
Upon activation of each device the intercom will beep twice confirming that the controller has received the test alarm. 
Each test alarm is printed and/or recorded in the Manager's Panel "Event Log". 
 
Once in Test Mode certain conditions have been set to cater for the activation of PIR's and radio devices. These are as 
follows; 
 
Radio devices should be tested first ‐ once any other hardwired device (excluding the PIR) is activated no further radio 
devices will be logged as tested. 
 
Hardwired PIR's are only reported every 30 seconds ‐ this is to allow movement through the accommodation to get to the 
next device without re‐triggering the PIR. 
 
When a ceiling pullcord is activated all pullcord reassurance LED's will be illuminated for 2 seconds. 
 
TO TURN THE ALARM BUTTON "GLOW" OFF
 
In standby mode the alarm         button will normally glow dim red and illuminate bright red when an alarm call is made.  
The standby glow can be turned on/off by pressing the          button. Note the alarm button will always illuminate bright red 
when an alarm call is made – this cannot be turned‐off. 
 

TO EXIT TEST MODE

 
The Test Mode duration is set at 10 minutes or it can be terminated at any time by pressing the          button once again.  
The intercom will then play 4 descending tones. 
 
 
 
 
 
 
 
 
Doc No. FM0410 issue M‐1 Page 21
 
 
 
 
         
 
 
 
 
 
 
IMPORTANT 
Only 1 intercom can be in Test Mode at any one time. 
Test Mode cannot be entered via a Remote Intercom. 
 
PRESS AND HOLD THE         BUTTON 
FOR ABOUT 5 SECONDS UNTIL THE 
INTERCOM BEEPS ONCE THEN 
RELEASE....
 
 
  
 
 
 
          
7 ASCENDING TONES WILL SOUND 
AND THE LED WILL FLASH WHITE 
WHEN TEST MODE IS ENABLED
 
 
 
 
 
 
 
 