The Kirk 400 multi cell option is suitable for medium/large sites using up to 4 base stations and up to 12 repeaters.
Up to 12 DECT telephones can be used on a multi cell system as standard, up to 30 with an additional licence.
KIRK 400 MULTI CELL CONFIGURATION
700VA
UPS
External Tel Line
Advent xt Line
Desk CLI
Telephone
PART NUMBERS
Part No.
ZXT548
ZXT556
ZXT549
ZXT504
ZXT536
ZXT512
ZXT523
ZXT524
ZCS766
ZCS729
W00525
F00040
POWER CONNECTION
To maintain DECT operation during a mains failure the Matrix and Fastswitch must both be powered from the 700VA UPS,
the Repeaters must be powered from a battery backed 12V DC power supply.
If the Matrix and Fastswitch are plugged directly into the mains and Repeaters are powered via in‐line PSU modules there
will be no DECT coverage during a mains failure; however the fixed CLI desk telephone will still operate.
FASTSWITCH CONNECTION
The 16 Port Fastswitch provides Power over Ethernet for the Kirk 400 Wireless Server and IP Base Stations.
POWER ‐ connect to the UPS via the in‐line PSU module provided.
PORTS 1 to 4 ‐ connect to the Kirk 400 Wireless Server and IP Base Stations (up to 100 metres of 4 pair Cat 5e cable).
PORT 9 ‐ connect to the Matrix ETHERNET port using the RJ45 patch lead provided.
Doc No. FM0410 issue M‐1 Page 51
16 Port Fastswitch
240V
AC
Matrix
IP PBX
See Tynetec Drg No. ZXT100 issue L sheet 8 for detailed connections
Description
700VA UPS
Matrix Eternity IP PBX
16 Port Fastswitch (8 x PoE)
Kirk 400 Wireless Server (Multi Cell)
IP 12 Channel Base Station
2 Channel Multi Cell Repeater
Spectralink 7202 DECT Phone & Charger
Spectralink 7212 DECT Phone & Charger
Desk CLI Telephone
Kirk Repeater Programming Kit
12V 2A Boxed PSU
12V 3.4Ah Rechargeable Battery
DECT Telephones (12 standard)
Kirk 400 Wireless
IP 12 Channel Base Stations (max 3)
Server (1 only)
Repeaters (max 3 per Server/Base = total 12)
12V DC PSU
240V
AC
Notes
1 per site
1 per site
1 per site
1 per site
max 3 per site
max 12 per site
max 12 (30 with
additional licence)
1 per site
1 off purchase
1 per 6 Repeaters
1 per PSU
2 Channel Multi Cell Repeaters