Tynetec Advent xt Installation Manual page 56

Warden call system
Hide thumbs Also See for Advent xt:
Table of Contents

Advertisement

 34. KIRK 6500 DECT 
 
 
FASTSWITCH CONNECTION
 
The 16 Port Fastswitch provides 8 PoE Ports (Power over Ethernet) for the IP Base Stations. 
 
POWER ‐ connect to the UPS via the in‐line PSU module provided. 
PORTS 1 to 8 ‐ connect to the IP base stations (up to 100 metres of 4 pair Cat 5e cable). 
PORT 9 ‐ connect to the Matrix ETHERNET port using the RJ45 patch lead provided. 
PORT 10 ‐ connect to Kirk 6500 Wireless Server using an RJ45 patch lead. 
 
Note; a second 16 Port Fastswitch (8 x PoE) can be connected to increase the number of IP base stations to 16. 
Connect the second Fastswitch to the UPS and link the 2 units via a Patch Lead between Ports 11. 
Alternatively a 24 Port Fastswitch (24 x PoE) is available – Tynetec Part No. ZXT559. 
 
MATRIX CONNECTION
 
The Matrix IP PBX interfaces the Advent xt to the DECT; it also gives access to an outside line and allows zoning of calls. 
 
24VDC ‐ connect to the UPS via the in‐line PSU module provided.  
CO1 ‐ connect to the Advent xt DECT output using the RJ11/BT lead provided. 
CO2 ‐ connect to an external line using the second RJ11/BT lead provided.  
SLT1 ‐ connect to the fixed CLI desk telephone via a BT master socket (Note: cut one plug off the RJ11/RJ11 lead provided).  
ETHERNET ‐ connect to the Fastswitch Port 9 using the RJ45 patch lead provided. 
        ‐ connect to a sound Earth terminal using the Earth wire provided 
 
The Matrix is factory programmed so all incoming lines ring all extensions. If an incoming line is to ring specific extensions 
then the Matrix must be reconfigured. 
 
Note; in the event of a mains failure i.e. if the UPS batteries run flat or if a UPS is not fitted, the Matrix connects CO1 to SLT1 
and the Advent xt will only ring the fixed CLI desk telephone. 
 
KIRK 6500 WIRELESS SERVER PROGRAMMING
 
The Matrix must have its IP address set to 192.168.0.2 
The Kirk 6500 Wireless Server must have its IP address set to 192.168.0.3 
IP 12 Channel Base Station IP addresses must start at 192.168.0.4 with Radio Part Numbers 4 and carry on sequentially. 
 
ADVENT xt PROGRAMMING
 
The PBX Ring must be enabled in the "General Setup" programming ‐ see the Advent xt Programming Manual (Tynetec Doc 
No. FM0411). 
 
4 CHANNEL MULTI CELL REPEATERS
 
A maximum of three 4 Channel Multi Cell Repeaters can be connected per IP Base Station. Repeaters require a power 
connection only; they communicate with the Base Station via low power radio signals and do not require a line connection. 
To maintain DECT coverage during a mains failure all Repeaters must be connected to a battery backed 12V DC PSU. See 
Repeater Deployment Rules on the following page. 
 
REPEATER POSITIONING
 
Before installing power cables to Repeater positions it is important that the optimum position for coverage is established. 
Register the Repeater onto the IP Base (see Kirk Programming Kit below) then with the Repeater powered from a battery 
walk away in the direction that cover is to be extended. When the red LED on the Repeater starts to flash it is out of range 
and must be moved back towards the IP Base by a minimum of 5 metres before selecting its final location. 
 
REPEATER PROGRAMMING
 
The Kirk Programming Kit (P/No. ZCS729) is required to program Repeaters, the kit consists of a double adapter and comms 
lead – the latest Service Tool PC software and user guide can be downloaded free of charge from; 
http://support.polycom.com/PolycomService/support/us/support/voice/dect/dect_base_stations.html 
 
 
 
 
 
 
 
 
 
 
 
Doc No. FM0410 issue M‐1 Page 56