 21. DIGITAL DOOR PANEL INSTALLATION
 
TERMINATION
 
See Tynetec Drg No. ZXT100 sheet 3 for detailed wiring connections;  
 
 
 
 
                
DOOR PANEL AMPLIFIER BOARD
 
 
 
 
 
 
 
 
 
 
 
 
 
          
 
 
 
 
 
 
LINK SETTINGS
 
LK1 selects a standard or fail safe lock type; a standard lock requires power to unlock (fail secure) whereas a fail safe lock 
requires power to lock (fail open). See below for other link settings.  
 
Link No.
 
A0436B ‐ LK1
A0436B ‐ LK2
A0436B ‐ LK3
A0436B ‐ LK4
A00418 ‐ LK4
 
The lock release duration is set in the "Door Entry Setup" programming; see the Advent xt Programming Manual (Tynetec 
Doc No. FM0411). 
 

8 WAY DIL SWITCH SETTINGS (SW2)

 
DIL switches 1 to 4 are used to set a unique door panel ID (1 to 16). Door panel ID's must start from 1 and run sequentially. 
DIL switches 5 to 8 select the door panel features should all be ON for Advent xt. 
 
DIL 
SW 
 
 
OFF
ON
OFF
 
 
OFF
OFF
ON
 
 
OFF
OFF
OFF
 
 
OFF
OFF
OFF
 
OFF
A‐F Button 
(Normal)
 
OFF
 

4 WAY DIL SWITCH SETTINGS (SW1)

 
DIL switches 1 to 4 are normally all OFF. Set DIL Switch 1 ON to disable the voice reassurance and revert to standard 
reassurance tones. DIL switches 3 to 4 have no function. 
 
 
 
Doc No. FM0410 issue M‐1 Page 31
 
 
Link Position "A"
 
 
fit for standard lock
 
no expander fitted
 
A00418 type expander
 
normal
 
normal
 
 
ON
OFF
ON
 
 
ON
OFF
OFF
 
 
OFF
ON
ON
 
 
OFF
OFF
OFF
ON for Digital Door Panel  ‐  OFF for Functional Door Panel
 
ON
Concierge 
 
Button
 
OFF
OFF = No Expander  ‐  ON = Expander Board Fitted
 
Terminal
Function
 
 
IP 1
Play Welcome Message 
IP 2
No Function
RELAY
Activates for duration of call
SP1
Warden Call Loudspeaker Audio
SP2
 
Mic
Warden Call Microphone Audio
 
 
12V
12V DC Supply for Door Panel
0V
0V Supply for Door Panel
TX+
RS485 Data +
TX‐
RS485 Data ‐
C1
Door Entry Audio to Door 
C2
Door Entry Audio to Phone
CONC
Concierge Call output
T/G
Tailgate input (N/C)
EXLK
External Lock input (N/O)
0V
Common for T/G & EXLK inputs
LKSP
Lock Supply Voltage 
LKRT
Lock Return Voltage 
+
Lock Power Supply +12V
Lock Power Supply 0V
Link Position "B"
 
fit for fail safe lock
expander board fitted
A00437 type expander
not used for Advent xt
no speech and no tones
Door Panel ID 
10 
OFF
ON
OFF
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
A‐F & Concierge 
 
ON
 
Not Connected
 
Not Connected
1 pair CW1308 to 
 
Advent xt Controller
1 wire CW1308 to 
 
Advent xt Controller
 
 
2 pairs CW1308 to 
Advent xt Controller
1 pair CW1308 to 
Advent xt Controller
1 pair CW1308 to  
 
Advent xt Controller
Not Connected
2 pairs CW1308 to 
PTE & Door Contact 
 
1.0 mm pair to local 
 
 
 
 
 
 
11 
12 
13 
14 
 
 
OFF
ON
OFF
ON
 
 
ON
ON
OFF
OFF
 
 
OFF
OFF
ON
ON
 
 
ON
ON
ON
ON
 
ON
Advent XT Manager 
 
Button
 
ON
Connection
0V Trigger
 
 
 
 
 
 
1.0 mm pair to 
 
Door Lock
 
Lock PSU
15 
16 
 
OFF
ON
 
ON
ON
 
ON
ON
 
ON
ON
 
Button