 30. KIRK 400 SOLO BASE DECT
 

MATRIX CONNECTION

 
The Matrix IP PBX interfaces the Advent xt to the DECT; it also gives access to an outside line and allows zoning of calls. 
 
24VDC ‐ connect to the UPS via the in‐line PSU module provided.  
CO1 ‐ connect to the Advent xt DECT output using the RJ11/BT lead provided. 
CO2 ‐ connect to an external line using the second RJ11/BT lead provided.  
SLT1 ‐ connect to the fixed CLI desk telephone via a BT master socket (Note: cut one plug off the RJ11/RJ11 lead provided).  
ETHERNET ‐ connect to the PoE injector using the RJ45 patch lead provided. 
        ‐ connect to a sound Earth terminal using the Earth wire provided 
 
The Matrix is factory programmed so all incoming lines ring all extensions. If an incoming line is to ring specific extensions 
then the Matrix must be reconfigured. 
 
Note; in the event of a mains failure i.e. if the UPS batteries run flat or if a UPS is not fitted, the Matrix connects CO1 to SLT1 
and the Advent xt will only ring the fixed CLI desk telephone. 
 
KIRK 400 WIRELESS SERVER (SOLO BASE) PROGRAMMING
 
The Matrix must have its IP address set to 192.168.0.2 
The Kirk 400 Wireless Server must have its IP address set to 192.168.0.3 and its Radio Part Number set to 3. 
 
ADVENT xt PROGRAMMING
 
The PBX Ring must be enabled in the "General Setup" programming ‐ see the Advent xt Programming Manual (Tynetec Doc 
No. FM0411). 
 

2 CHANNEL MULTI CELL REPEATERS

 
A maximum of six 2 Channel Multi Cell Repeaters can be used with the Kirk 400 Wireless Server Solo Base. Repeaters 
require a power connection only; they communicate with the Solo Base via low power radio signals and do not require a 
line connection. To maintain DECT coverage during a mains failure all Repeaters must be connected to a battery backed 
12V DC PSU. See Repeater Deployment Rules on the following page. 
 

REPEATER POSITIONING

 
Before installing power cables to Repeater positions it is important that the optimum position for coverage is established. 
Register the Repeater onto the Solo Base (see Kirk Programming Kit below) then with the Repeater powered from a battery 
walk away in the direction that cover is to be extended. When the red LED on the Repeater starts to flash it is out of range 
and must be moved back towards the Solo Base by a minimum of 5 metres before selecting its final location. 
 
REPEATER PROGRAMMING
 
A Kirk Programming Kit (P/No. ZCS729) is required to program Repeaters, the kit consists of a double adapter and comms 
lead – the latest Service Tool PC software and user guide can be downloaded free of charge from; 
http://support.polycom.com/PolycomService/support/us/support/voice/dect/dect_base_stations.html 
 
REPEATER POWER CONNECTION
 
Repeaters should be connected using 1.0 mm pair cabling, if CW1308 is being used then spare pairs can be doubled‐up 
and/or looped back to form a ring circuit to reduce the voltage drop.  
 
 
12V DC PSU including 
 
     Standby Battery 
 
 
 
 
 
 
 
240V 
  AC  
 
 
Use 1.0mm Cable 
 
 
Typically the maximum distance to a Repeater via CW1308 should not exceed 100 metres.  
 
 
 
Doc No. FM0410 issue M‐1 Page 46
 
Maximum 6 x 2 Channel Multi Cell Repeaters 
   
Repeater Power Lead Colour Code  
   YELLOW = 12V  BLACK = 0V 