6. NETWORK TERMINATION BOARD
The Advent xt termination board provides the interface between the main CPU board and the site wiring network.
RS232
PORT 2 SETTINGS OUTPUTS FUSES
JP2
RIBBON TO
CPU BOARD
RS232
PORT 1
SMPSU INPUTS
RS232 PORTS
The standard 9 pin "D" RS232 port 1 is used to connect a laptop PC to monitor the network comms using Windows Hyper
Terminal (19200 baud, 8 data bits, 1 stop bit, no parity). The second RS232 port 2 (MMJ data socket) is used to connect a
Tynetec interface (P/No. ZXT295) to program network devices in‐circuit (this is provided with a Windows utility which can
also be used to monitor network comms). The correct link settings LK1‐LK6 must be selected depending on what the RS232
port is being used for.
LINK SETTINGS
Links LK1 to LK6 will normally be fitted as shown on the drawing above. These settings allow either RS232 port to be used
to monitor the Advent xt network data via Windows Hyper Terminal or the Tynetec interface. If the RS232 port 2 (MMJ
data socket) is being used to program network devices then the link settings must be changed as below. Link 7 has no
current function ‐ leave fitted in position A.
RS232 Port Mode
Monitor Advent xt Comms
Monitor Altera Comms
Program Advent xt Network
Program Altera I/O Units
INPUTS
There are 4 inputs which can be activated by switching 0V via normally open clean contacts into terminals IP1‐IP4.
The "Brigade output" relay on the building's Fire Alarm Panel can be connected to input 4 to report fire alarms via the
Advent xt system.
Doc No. FM0410 issue M‐1 Page 10
LINK 1‐6 INPUTS
EXT PSU INPUTS
Link Settings
Input No.
IP1
IP2
IP3
IP4
XT
NETWORK
AUDIO INPUT PA & D/E I/P LINK 7
LK1A
LK2A
LK3B
LK1B
LK2B
LK3B
LK1A
LK2A
LK3A
LK1B
LK2B
LK3B
Function
Spare
Spare
Spare
Fire Alarm Tone
ALTERA
NETWORK
LK4B
LK5B
LK6B
LK4B
LK5B
LK6B
LK4A
LK5B
LK6B
LK4B
LK5A
LK6A
NETWORK 1
NETWORK 2
NETWORK 3