23. COMBINED INTERCOM INSTALLATION
HARD OF HEARING STROBES & VOLUME
Two hard of hearing strobes can be connected to a combined intercom. An amber strobe (P/No. ZSL041) can be connected
to indicate a door entry call and a blue strobe (P/No. ZSL046) can be connected to indicate when the warden is calling.
Note; a maximum of 2 strobes per flat is permitted. See the Advent xt wiring diagram Drg No. ZXT100 sheet 5.
The volume of speech at the combined intercom can be increased using VR1.
BUTTON FUNCTIONS AND LED COLOURS
The LED's on the front of the combined intercom unit indicate the following modes;
PRIVACY MODE
Press the Privacy button once to select privacy mode, the LED will illuminate STEADY AMBER. The Manager cannot
hear the resident and the resident will not receive any door entry calls when privacy mode is selected. Press the Privacy
button again to turn privacy mode off. Privacy can operate as a simple on/off action or with a timed auto‐reset.
The privacy auto‐reset time must be set in the "Door Entry Setup" programming ‐ see the Advent xt Programming Manual
(Tynetec Doc No. FM0411). Note: the privacy setting applies to both door entry and warden call mode.
LEARNING THE OPTIONAL REMOTE CONTROL
The Advent xt system must be operational before attempting to learn the Remote Control.
1. Press and hold the Test Mode button for 5 seconds until the unit beeps once, release the button and an upward
series of tones will play, the LED will illuminate
2. Press the Lock Release button once, an upward series of tones will play and the LED illuminates STEADY GREEN.
You now have 15 seconds to learn the Remote Control ‐ up to 2 Remotes can be learned per combined intercom.
3. Press the OPEN button on the Remote Control, an upward series of tones will play and the Speak/Listen button
AMBER LED will flash once. If the Remote is already registered a downward series of tones will be heard.
4. Learn mode will be exited after the second Remote is learned, or when the 15 second period times‐out, or if the
Lock button on the intercom is pressed. A downward series of tones will be heard.
5. Press the Test Mode button once to exit.
DELETING THE REMOTE CONTROL
1. Press and hold the Test Mode button for 5 seconds until the unit beeps once, release the button and an upward
series of tones will play, the LED will illuminate
2. Press the Lock Release button once, an upward series of tones will play and the LED illuminates STEADY GREEN.
You now have 15 seconds to delete the Remote Controls.
3. Press the Privacy button once, a downward series of tones will play and all Remote Controls are deleted.
4. Press the Test Mode button once to exit.
REMOTE CONTROL BATTERY LOW WARNING
If the Test Mode LED is
The low battery warning will continue until the battery is replaced and the Remote Control is used.
Remove the screw from the rear of the remote control case and replace the CR2032 3V Lithium cell.
Doc No. FM0410 issue M‐1 Page 37
Button
Function
I'm OK
Privacy
Play Message
Test Mode
Door Open
Talk (Door Entry)
Alarm
STEADY WHITE
STEADY WHITE
FLASHING WHITE
then the battery in the Remote Control needs replacing.
LED Colour/Pattern
Flashing Green = I'm OK period
Steady Amber = Privacy Mode selected
Flashing Blue = Message Waiting
White = unit in wardens Test Mode
Flashing White = Remote Control battery low
Steady Green = Door Lock Released
Flashing Green = Door Left Open
Flashing Amber = Door Entry "Speak to Door" mode
Steady Amber = Door Entry "Listen to Door" mode
Dim Red = normal operating mode
Steady Bright Red = Alarm Call in progress
Flashing Bright Red = Awaiting Extracare cancellation
.
.