 25. BT LINE SELECTOR INSTALLATION
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INSTALLATION
 
The BT Line Monitor Unit is housed in a wall mounted ABS enclosure; 85 x 170 x 35 mm (HxWxD).  
 
TERMINATION
 
Connect the BT LINE socket to the Advent xt controller PSTN LINE socket using the BT lead provided.  
Connect the 12V & EN terminals to the Advent xt termination board OP3 using 1 pair CW1308 cable as shown above.  
The PRIMARY and SECONDARY sockets are connected to the 2 BT lines using the BT leads provided.  
If a GSM Cellular Terminal is being used then this should be connected to the SECONDARY socket – see below. 
 
PROGRAMMING
 
The "Secondary BT Line" must be enabled (01) in the "Remote Offsite" programming. 
DTMF Channel 003 must be disabled (FF) in "DTMF Channels" programming. 
If you are using Local Offsite Mode then the GSM Line Enable must be set (01) in the "Local Offsite" programming and 
Local Offsite Mode must also be enabled using the telephone; enter code 5007 followed by the  key.  
See the Advent xt Programming Manual (Tynetec Doc No. FM0411). 
 

GSM CELLULAR TERMINAL

 
The GSM Cellular Terminal ( P/No. W02121) is connected to the SECONDARY output of the  
BT Line Selector using the BT lead and RJ11/BT adapter ‐see below.  
 
        USB Charger Socket 
 
             Antenna Socket 
 
 
 
 
           TEL Socket 
 
Plug the RJ11/BT adapter provided with the GSM module into the TEL Socket then connect to BT Line Selector SECONDARY 
Socket using the BT lead. 
Connect the USB Charger and antenna provided with the GSM module then plug into a mains supply.  
Refer to the Burnside Telecom TX‐2LR user guide for setup details. 
 
Doc No. FM0410 issue M‐1 Page 39
 
The BT Line Selector (P/No. ZXT330) can be connected to the 
Advent xt controller if a second dedicated BT line or a GSM 
cellular terminal is specified for fail safe operation.  
 
If the primary line fails the secondary line will automatically be 
selected, once the primary line is restored the system will 
automatically switch back. 
ZXT100
ADVENT XT CONTROLLER
ZXT330
ADVENT XT LINE SELECTOR