• Connections III and IV in the base for hose-free, direct connec-
tion to the machine table or on the base plate
The threads for hose-free, direct connection are not designed for
pneumatic fittings.
Threads for pneumatic fittings (front):
KSPplus 100-BWM, KSP-LH plus 100-BWM: M5
KSPplus 100-BWM, KSP-LH plus 160-BWM: G1/8"
KSPplus 250-BWM, KSP-LH plus 250-BWM: G1/8"
NOTE:
All four air connections come sealed on delivery of the clamping
block. At base with set-screws (23) and on front with locking
screws (11).
Requirements for the compressed air supply: Compressed air,
compressed air quality according to ISO 8573-1:7 4 4
Unconditioned compressed air contains moisture and dust and oil
particles that can lead to malfunctions or premature wear in the
clamping block. The oiler should be no more than 2 meters from
the coupling point.
The clamping block has two more base connections (V) for direct
lubrication through the machine table. These connections come
sealed on delivery with set-screws (24).
7.3

Assembling the clamping block on the base plate

(If the two parts are delivered separately)
When assembling PLUS series TANDEM clamping blocks onto
ABP-h, ABP-a or SBP TANDEM base plates, use the shorter mount-
ing screws included in the base plate accessory pack instead of the
standard mounting screws (19) that come with the clamping block.
For KSPplus 100-BWM: Use the M8x30 screws from the base plate
accessory pack instead of the M8x35 screws (19).
For KSPplus 160-BWM: Use the M10x35 screws from the base
plate accessory pack instead of the M10x40 screws (19).
For KSPplus 250-BWM: Use the M12x40 screws from the base
plate accessory pack instead of the M12x45 screws (19).
NOTE:
If the clamping system and base plate are ordered separately, the
screws, O-rings and clamping sleeves for assembling the parts are
included in the accessory pack that comes with the clamping block.
• Do not open the connections on the front of the clamping block
(I, II) or seal them with suitable dummy plugs (M5 or G1/8").