Beater Rotation

NOTICE! Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
To correct the rotation on a three-phase machine,
interchange any two incoming power supply lines at the
freezer main terminal block only. To correct rotation on a
single-phase machine, exchange leads inside the beater
motor. (Follow the diagram printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box located behind the
service panel.
It is recommended that beater rotation adjustment be
performed by an authorized Taylor service technician.

Refrigerant

CAUTION! In consideration of our environment,
Taylor uses only earth-friendly HFC refrigerants. The
HFC refrigerant used in this machine is R404A. This
refrigerant is generally considered nontoxic and
nonflammable, with an ozone-depleting potential (ODP)
of zero (0). However, any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
CAUTION! Use only R404A refrigerant that
conforms to the AHRI standard 700 specification. The
use of any other refrigerant may expose users and
operators to unexpected safety hazards.
To the Installer
WARNING! Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush the area immediately with cold water. If burns are
severe, apply ice packs and contact a physician
immediately.
NOTICE! Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
IMPORTANT! R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
Model 432
TO THE INSTALLER
1-3