Appendix C. Remote Module Command Structure - Geokon GK-405 Instruction Manual

Vibrating wire readot
Hide thumbs Also See for GK-405:
Table of Contents

Advertisement

64

APPENDIX C. REMOTE MODULE COMMAND STRUCTURE

COMMAND
0
1
2
3
4
5
6
7
8
9
REQUEST 6 READS
V6
V6%
SET GAGES SPECTRUM
V7
V8
TAKE +5V READING
SENSOR TEMPERATURE
VT
Example 1: READ FIRMWARE VERSION
Reads the firmware version of the Remote Module:
Command:
4<CR>
Response:
Geokon405 Ver1.0 0320
Example 2: REQUEST 6 READS:
Get sensor readings for up to six Vibrating Wire "cells"
("0000000" returned for unconnected gages):
Command:
V6<CR>
Response:
0200000 0000000 0000000 0000000 0000000 0000000
Notes:
• The above response shows that there is one gage (of six) connected
• Raw gage values are in units of nanoseconds
• Frequency (F, in Hz) = 1 / T (sec); F = 1 / 0.0002 = 5000 Hz
• Digits = F2/1000 = (5000)2/1000 = 25000
FUNCTION
N/A
N/A
N/A
N/A
READ FIRMWARE
VERSION
N/A
N/A
N/A
N/A
N/A
TAKE BATTERY
READING
(°C)
Table 7 - Remote Module Command Format
SYNTAX
RETURN VALUE
4
####### 0000000 0000000
V6
0000000 0000000 0000000
V6(A –
F)
V7
V8
VT
VER#.#
%%%%%%
<sp><sp>+#.#
<sp><sp>+#.#
(+/-)##.####

Advertisement

Table of Contents
loading

Table of Contents