Sign In
Upload
Manuals
Brands
Geokon Manuals
Measuring Instruments
GK-604D
User Manuals: Geokon GK-604D Inclinometer
Manuals and User Guides for Geokon GK-604D Inclinometer. We have
5
Geokon GK-604D Inclinometer manuals available for free PDF download: User Manual, Instruction Manual, Quick Start Manual
Geokon GK-604D User Manual (117 pages)
Inclinometer Readout Application
Brand:
Geokon
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
5
1 Introduction
13
Features
13
Figure 1 - Model GK-604D, Digital Inclinometer System
13
Figure 2 - Model 6000-2 Control Cable (Top)
14
GK-604D Inclinometer Readout Application
15
Figure 3 - FPC-1 Running GK-604D IRA
15
Figure 4 - 6000/6100 Type Probe
16
Figure 5 - GK-604-4 Interface
16
Figure 6 - GK-604-3 Reel System (Shown with the Archer Unit and Carrying Case)
17
Tiltmeter and Compass Probes
17
Before Using the GK-604D Inclinometer Readout
18
2 Installation and Operation
19
Initial Quick Start Sequence
19
Figure 7 - Probe Settings Mismatch
21
Figure 8 - Initial Probe Settings
22
Figure 9 - no Probe Association Window
22
Establishing Contact with the Remote Module
24
Installing the GK-604D IRA
27
Figure 10 - Activesync Window Showing Active Connection
27
Figure 11 - Windows Mobile Device Center
28
Figure 12 - Windows Explorer Window Displaying HHD Root Folder
29
Launching the GK-604D Installer
29
Figure 13 - Hand-Held Device Root Folder Contents
30
Figure 14 - Installation Folder Contents
30
Figure 15 - GK-604D Installer at Root of HDD
31
Figure 16 - GK-604D Install Screen
32
Figure 17 - GK-604D IRA Icon in Start->Program
32
Starting the Inclinometer Readout the First Time
33
Figure 18 - Select Workspace Name
33
Figure 19 - Select Workspace Folder
34
Figure 20 - Workspace Exists
34
Figure 21 - Select Probe Library Name
35
Figure 22 - Select Probe Library Folder
36
Figure 23 - Probe Library Exists
36
Figure 24 - Empty Workspace and Probe Library
37
3 User Interface
38
Overview
38
Figure 25 - User Interface
38
Project Explorer
39
Context Menu
40
Figure 26 - Context Menu
40
Application Menu
41
Live Readings
41
Figure 27 - Application Menu
41
Figure 28 - Remote Module Connection Problem
42
Figure 29 - Live Readings Screen
42
Figure 30 - Unsaved Data Prompt
43
Figure 31 - Auto Increment Save
43
Figure 32 - Save File Screen
44
Figure 33- Menu Option (Live Readings Screen)
44
Figure 34 - Viewing Inclinometer Data
45
Figure 35 - Viewing Compass Data
46
Edit Settings
47
Terminal Window
47
Figure 36 - Terminal Window
47
About GK-604D
49
Figure 37 - about GK-604D IRA
49
Figure 38 - Ready for Connection
49
Figure 39 - Remote Module/Probe Status
50
System Configuration
51
Figure 40 - System Configuration
51
Figure 41 - Stable Indication
52
Figure 42 - Unstable Indication
52
Figure 43 - Auto Record Enabled
54
Figure 44 - Auto Record Active
54
Figure 45 - Auto Record Paused, Dataset 2 Selected
56
File Menu
59
Export Menu
59
Figure 46 - File Menu Figure 47 - Export Menu
59
Figure 48- Export Data Window Figure 49 - Save Data File
60
Figure 50 - Export Path Selection Figure 51 - Probe Selection Window
61
Import Menu
62
Figure 52 - Import Menu Figure 53 - Select Hole Export File
62
Figure 54 - Select Project Export File Figure 55 - Select Probe Export File
63
Figure 56 - Select Probe Library Export File Figure 57 - Probe Library Switch after Import
64
View Data
65
Figure 58 - Select View Options Window Figure 59 - View Option List
65
Figure 60 - Menu Options for Reports Figure 61 - Raw Data Report
66
Figure 62 - Axis Profile Report Figure 63 - Axis Deflection Report
66
Figure 64 - Profile Plot Figure 65 - Profile Plot - Marker on
67
Delete/Restore Menu
68
Figure 66 - Deflection Plot
68
Exit
69
Figure 67 - Delete / Restore Window Figure 68 - Hole Delete / Restore Window
69
4 Configuring Project Explorer Elements
70
Hole Configuration
71
Figure 69 - Hole General Settings
71
Figure 70 - Hole Parameters
71
Probe Configuration
72
Figure 71 - Probe General Settings
72
Figure 72 - Probe Coefficients
72
Project Configuration
74
Figure 73 - Project Settings
74
5 Files, Folders and Transferring Data
75
File Transfer
76
Backing up Configurations
76
APPENDIX A. Inclinometer Theory
77
Inclinometer Theory
77
Figure 74 - Inclinometer Casing (End View)
77
Figure 75 - Inclinometer Probe
78
Figure 76 - Inclinometer Survey Description
79
Figure 77 - Plot of Borehole Deflection
79
Conducting the Survey
80
Checksums and "Face Errors" on Inclinometer Probes
81
Effect of "Face Error" on Reading Accuracy
82
Measurement of "Face Error
83
Setting of the "Face Error" to Zero
83
Conclusion
84
APPENDIX B. Data File Format
85
Hole Data File Format
85
APPENDIX C. Text Reports
87
Raw Data Text Report
87
A-Axis Profile Data Text Report
88
B-Axis Profile Data Text Report
89
A-Axis Deflection Data Text Report
90
B-Axis Deflection Data Text Report
91
APPENDIX D. Remote Module Command Structure
93
APPENDIX E. Data Reduction Formulas
95
Deflection Calculation
95
Profile Calculation
97
GTILT Users
98
APPENDIX F. Technical Specifications
99
GK-604D Digital System Specifications
99
F1.1 Compass Sensor Specifications
100
Analog Probe System Specifications
101
Field PC (FPC-1) Specifications
102
APPENDIX G. Tiltmeter Operation (Model 6101)
103
Figure 78 - Model 6101 Tiltmeter with 6201-3 Interface Cable
103
Figure 79 - Tiltplates: 6201-1C (Ceramic), 6201-1A (Copper Plated Aluminum), 6201-1S (Stainless)
104
Figure 80 - Live Readings (Tiltmeter)
106
Figure 81 - Saving Data Query
106
Figure 82 - Save File Dialog
107
Figure 83 - File Exists Dialog
107
Tiltmeter Data Format
108
APPENDIX H. Spiral and Compass Probe Operation
109
Spiral Indicator Probe (6005-3)
109
Figure 84 - Spiral Indicator Probe (6005-3)
109
Figure 85 - Live Readings for Spiral Data
110
Figure 86 - Saving Compass Survey Data
111
Inclinometer/Compass Probe (6100D-X)
112
Figure 87 - Digital Inclinometer/Compass Probe (6100D-X)
112
Figure 88 - Compass Enable Message
113
Figure 89 - Live Compass Data
114
Calibrate Compass
115
Figure 90 - Initial Calibration Screen
115
Figure 91 - Calibration Routine
116
Spiral Indicator Data
117
Compass Survey Data
117
Advertisement
Geokon GK-604D User Manual (116 pages)
Inclinometer
Brand:
Geokon
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
5
1 Introduction
13
Figure 1 - Model GK-604D, Digital Inclinometer System
13
Features
14
Figure 2 - Model 6000-2 Control Cable (Top)
14
Figure 3 - Pulley Style Cable Grip
15
Figure 4 - Cable Holds (Obsolete)
15
GK-604D | Aos
16
Figure 5 - Android Field Device Running GK-604D|Aos
16
Compass Probes
17
Figure 6 - 6000/6100 Type Probe
17
Figure 7 - GK-604-4 Interface
17
Before Using the GK-604D|Aos
18
2 Installation and Operation
19
Initial Start Sequence
19
Figure 8- New Probe Found
21
Figure 9 - Initial Probe Settings
21
Figure 10 - no Probe Association Screen
22
Establishing Contact with the Remote Module
23
Figure 11 - Android Device Settings Screen
23
Figure 12 - Bluetooth Pairing Screen
24
Figure 13 - Bluetooth Pairing Request Screen
25
Figure 14 - Paired Devices
25
Installing the GK-604D | Aos Application
26
Installing GK-604D | Aos from Google Playstore
27
Figure 15 - Google Play Store Application
27
Figure 16 - Geokon GK-604D | Aos Install Screen
28
Installing GK-604D | Aos Via USB Link to Host PC
29
Starting the GK-604D | Aos for the First Time
30
Figure 17 - Initial Screen
30
Figure 18 - Workspace Settings Screen
31
Figure 19 - Probe Library Settings Screen
32
Figure 20 - Workspace and Probe Library Created
33
Figure 21 - Select Workspace
34
Figure 22 - Projects Screen
35
Figure 23 - Holes Screen
35
Figure 24 - Hole Settings Screen
36
3 User Interface
37
Overview
37
Figure 25 - Main Screen
37
APP Menu
38
Figure 26 - APP Menu
38
Figure 27 - Remote Module Power-On Reminder
39
Live Readings
39
Figure 28 - Remote Module Connection Problem
40
Figure 29 - Temporary File Data Prompt
41
Figure 30 - Live Readings Screen
42
Figure 31 - Unsaved Data Prompt
43
Figure 32 - Saving Temporary Data
44
Figure 33 - Load Previous Data Prompt
44
Figure 34- Menu Options (Live Readings Screen)
45
Figure 35 - Live Readings Menu Options (Compass Enabled)
46
Figure 36 - Viewing Compass Data
47
Figure 37 - Viewing Inclinometer Data
47
Figure 38 - View Previous Survey
48
Figure 39 - Meta Data Editor
49
Figure 40 - Meta Data Editor (Screen 2)
49
Figure 41 - Terminal Window
50
Terminal Window
50
About GK-604D
51
Figure 42 - about GK-604D IRA
51
Figure 43 - Remote Module/Probe Status
52
Figure 44 - System Configuration
53
System Configuration
53
Figure 45 - Unstable Indication
54
FILE Menu
58
Export Menu
58
Figure 46 - File Menu
58
Figure 47 - Survey Export Options
59
Figure 48 - Survey List
60
Figure 49 - Export Folder Selection
60
Figure 50 - Share Via Screen
61
Figure 51 - Email Message Screen
62
Import Menu
63
Figure 52 - Import File Selection
63
Figure 53 - Importing Screen
64
View Data
66
Figure 54 - Select View Options Screen
66
Figure 55 - Report Type List
67
Figure 56 - View Options Screen (Selecting 2 Surveys)
67
Figure 57 - Raw Data Report
68
Figure 58 - Axis Profile Report
69
Figure 59 - Axis Deflection Report
70
Figure 60 - Axis Profile Plot
71
Figure 61 - Axis Deflection Plot
72
Delete
73
Figure 62 - Delete Warning Message
73
4 Configuration Elements
74
Hole Configuration
75
Figure 63 - Hole Parameters (Screen 1)
76
Figure 64 - Hole Parameters (Screen 2)
77
Probe Configuration
78
Figure 65 - Probe Parameters Screen
79
Figure 66 - Upload Settings
79
Project Configuration
80
Figure 67 - Project Parameters Screen
80
5 Files, Folders and Transferring Data
81
File Transfer
81
6 Maintenance
82
O-Ring
82
Wheel Assemblies
82
Figure 68 - Wheel Lubricant (ADH-106 Belray Waterproof Grease Type 99540)
82
Figure 69 - Greasing Wheels
82
Water Entry
83
Zero Shift Changes
83
Self Calibration Check
83
7 Troubleshooting
84
Probe Connection Failure
84
Figure 70 - Probe Connection Failure
84
Common Troubleshooting Solutions
86
APPENDIX A. Inclinometer Theory
87
Inclinometer Theory
87
Figure 71 - Inclinometer Casing (End View)
87
Figure 72 - Inclinometer Probe
88
Figure 73 - Inclinometer Survey Description
89
Figure 74 - Plot of Borehole Deflection
89
Conducting the Survey
90
Checksums and "Face Errors" on Inclinometer Probes
91
Effect of "Face Error" on Reading Accuracy
92
Measurement of "Face Error
93
Setting of the "Face Error" to Zero
93
Conclusion
94
APPENDIX B. Data File Format
95
Hole Data .GKN File Format
95
APPENDIX C. Text Reports
97
Axis Profile Data Report (.CSV)
97
Axis Deflection Data Report (.CSV)
98
APPENDIX D. Remote Module Command Structure
99
APPENDIX E. Data Reduction Formulas
102
Deflection Calculation
102
Profile Calculation
104
GTILT Users
105
Sitemaster Users
105
APPENDIX F. Technical Specifications
106
GK-604D Digital System Specifications
106
Compass Sensor Specifications
107
Analog Probe System Specifications
108
Android Device Minimum Specifications
109
APPENDIX G. Compass Probe Operation
110
Inclinometer/Compass Probe (6100D-X)
110
Figure 75 - Digital Inclinometer/Compass Probe (6100D-X)
110
Figure 76 - Compass Enable Message
112
Figure 77 - Live Compass Data
113
Calibrate Compass
114
Compass Survey Data
116
Geokon GK-604D Instruction Manual (64 pages)
Digital Inclinometer Reader Application
Brand:
Geokon
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
5
Introduction
11
Readout Unit
11
Gk-604D Reader Application
11
Figure 1: FPC-3 Running the GK-604D Reader App
11
Installation and Operation
12
Before Using the Gk-604D Reader Application
12
Installing the Gk-604D Reader App
12
Installing Gk-604D Reader from Google Play Store
12
Figure 2: GK-604D Reader Icon
12
Figure 3: Google Play Icon
12
Installing Gk-604D Reader Via Usb Link to Host Pc
13
Figure 4: GK-604D Install Page
13
Starting the Gk-604D Reader App the First Time
14
Figure 5: Permission Request
14
Figure 6: Main Screen
14
Creating a New "Hole
15
Figure 7: Main Screen "Kebab" Menu Items
15
Figure 8: Holes Screen
15
Figure 9: Hole Editor Screen
16
Figure 10: Holes Screen (with New Hole Shown)
16
Setting the System Parameters
17
Stable Indication
17
Stability Filter
17
Figure 11: System Settings Editor
17
Stable Sound
18
Unstable Sound
18
Auto Record Data
18
Finish Survey with
18
Bluetooth Device
18
Email Address
18
Gk-604D Reader Application Main Screen
19
Overview
19
Connecting to the Reel and Conducting Asurvey
20
Figure 12: Live Readings Screen
20
Figure 13: Problem Connecting to Reel
21
Figure 14: New Probe Found
21
Figure 15: Inclinometer Editor
22
Figure 16: Probe Not Assigned
22
Live Readings Window
23
Figure 17: Live Inclinometer Data
23
Figure 18: Data History
23
Live Readings Screen Kebab Options
24
Figure 19: Survey Status and RECORD Button (STABLE)
24
Figure 20: Survey Status and RECORD Button (UNSTABLE)
24
Figure 21: Live Readings "Kebab" Options
24
Figure 22: Previous Survey Data Viewer
25
Figure 23: Meta Data Editor
25
Figure 24: Initial Compass Calibration Screen
26
Figure 25: Calibration In-Process Screen
26
Conducting a Survey
27
Auto Record Sequence
29
Figure 26: Auto Record Enabled
29
Figure 27: Auto Record Is Active
29
Figure 28: Auto Record Paused, Dataset 2 Selected
30
Figure 29: Unsaved Data Prompt
31
Working with Application Configuration Elements
32
Hole Configuration
32
Figure 30: Edit Hole Parameters, Screen 1
33
Figure 31: Edit Hole Parameters, Screen 2
33
Inclinometer Configuration
34
Project Configuration
35
Figure 32: Edit Inclinometer Parameters
35
Figure 33: Project Parameters
35
Importing and Sharing (Exporting)
36
Import
36
Figure 34: Import Screen
36
Figure 35: Import File Selection
36
Figure 36: Importing Page
37
Sharing (Exporting)
38
Figure 37: Importing Page, Import Done
38
Figure 38: Survey Export Options
38
Figure 39: Survey List
39
Figure 40: Select Survey Export Method
39
Figure 41: Folder Chooser
40
Figure 42: Choose Email Provider
40
Figure 43: Email Composer
41
Plots/Reports
42
Figure 44: Plots/Reports Screen
42
Figure 45: Two Surveys Selected
42
Raw Data File Report
43
Axis Profile Report
43
Figure 46: Report Types List
43
Figure 47: Raw Data Report (Landscape View)
43
Axis Deflection Report
44
Figure 48: Profile Report (Landscape View)
44
Figure 49: Deflection Report (Portrait View)
44
Figure 50: Deflection Report
44
Axis Profile Plot
45
Axis Deflection Plot
45
Figure 51: a & B Axis Profile Plot
45
Figure 52: a & B Axis Deflection Plots
45
Terminal Window Page
46
Figure 53: Terminal Window Page
46
Figure 54: Terminal Window Page (Connected)
46
Database Backup
47
Figure 55: Android Folder Choose
47
About Gk-604D Reader
48
Figure 56: about GK-604D Reader
48
Figure 57: Attempting to Connect Dialog
48
Figure 58: about GK-604D with Probe Status
49
Appendix A. Hole Data Gkn File Format
50
Table 1: Hole Data GKN File Format
50
Appendix B. Text Reports
51
Raw Data Text Report
51
Table 2: Raw Data Text Report
51
A-Axis Profile Data Text Report
52
Table 3: Axis a Profile Data Text Report
52
B-Axis Profile Data Text Report
53
Table 4: Axis B Profile Data Text Report
53
A-Axis Deflection Data Text Report
54
Table 5: Axis a Deflection Data Text Report
54
B-Axis Deflection Data Text Report
55
Table 6: Axis B Deflection Data Text Report
55
Compass Survey Data Text Report
56
Table 7: Compass Survey Data Text Report
56
Appendix C. Remote Module Command Structure
57
Table 8: Remote Module Commands
57
Appendix D. Data Reduction Formulas
59
Deflection Calculation
59
Profile Calculation
59
Table 9: Data Reduction Variables (Deflection)
59
Table 10: Data Reduction Variables (Profile)
59
Equation 1: Change in Digits Calculation (Deflection)
59
Equation 2: Deflection Calculation
59
Gtilt Users
60
Sitemaster Users
60
Equation 3: Change in Digits Calculation (Profile)
60
Equation 4: Profile Calculation
60
Advertisement
Geokon GK-604D Quick Start Manual (6 pages)
Digital Inclinometer System
Brand:
Geokon
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Introduction
1
Starting the Gk-604D Reader App the First Time
1
Creating a New “Hole”
2
Connecting to the Remote Module
3
Enable Compass Survey
4
Conducting a Survey
4
Geokon GK-604D Quick Start Manual (4 pages)
Digital Inclinometer
Brand:
Geokon
| Category:
Measuring Instruments
| Size: 0 MB
Advertisement
Related Products
Geokon GK-604D aos
Geokon GK-405
Geokon GK-604
Geokon GK-404
Geokon GK-401
Geokon 1100
Geokon 1133911
Geokon 1140741
Geokon 1300
Geokon 1900
Geokon Categories
Measuring Instruments
Accessories
Data Loggers
Network Hardware
Transducer
More Geokon Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL