3.3 Mounting the Drive

Mount the drive upright on a flat, vertical, level surface using Table 3-2 NEMA 12 / IP55 Dimensions
for mounting locations.

3.3.1 Protecting the Drive from Debris

The drive is designed to operate in NEMA 12 (IP55) Type installations.

3.3.2 Watts Loss Data

Refer to Table 2-1 for watts loss data.

3.3.3 Elevation

Maximum elevation is 3300 ft (1000m) above sea level without de-rating. De-rate output power by
1% per 330 ft (100m) about 3300 ft to 6600 ft (2000m) maximum elevation.

3.4 Cover Removal

To connect power and signal wires, the cover must be removed as shown in Figure 3-1.
3-2 Installing the Drive
Figure 3-1 Cover Removal
Press in (cover release)
then lift cover to remove.