1.3 Quick Start
Frame B
(VS1MXS51 shown
as an example)
Power Up Procedure (Refer to Chapter 3, 4 and 5 for additional details.
1. Remove all power from the control.
2. Couple the motor to its load.
3. Verify freedom of motion of motor shaft.
4. Verify the motor coupling is tight without backlash.
5. Connect input control wires and output control wires, See Figure 1-2.
6. (Switched Version) Place Direction Command switches in OFF Position.
(Keypad version) Connect a control switch between terminals 1 and 2 ensuring that the contact is
open (drive disabled)
7. Connect Power & Motor wires to the control, See Figure 1-1.
8. Turn power on. Be sure there are no faults. For switched version, place the Power On/Off switch in
ON position.
9. Set the following parameters for the values displayed on the motor nameplate:
P1-01 Motor Rated Voltage
P1-02 Motor Rated Current
P1-03 Motor Rated Frequency
P1-04 Motor Rated Speed
10. (Switched Version) set P1-07 Start/Stop Source to 0.
(Keypad version) set P1-07 Start/Stop Source to 1 or 2.
11. Verify the holding brakes if any, are properly adjusted to fully release and set to the desired torque.
12. (Switched version) Run the drive from the front panel controls.
(Keypad version) Enable the drive by closing the switch between control terminals 1 & 2. Run the
drive from the keypad.
13. Select and program additional parameters to suit your application, see Chapter 7.
The control is now ready for use. If a different operating mode is desired, refer to Chapter 7 Parameter
Descriptions and Chapter 8 Customizing for your Application.
MN762S
Figure 1-1 Power & Motor Terminal Locations
Frame B
See Recommended Tightening
Torques in Table 4-1.
L1/L L2/N L3
U
V
W
+
BR
Introduction 1-3