H If multiple units are being mounted side by side, a spacing of 0.5" (13mm) must be provided
between the units and from the unit to the side of the cabinet / enclosure.
H To comply with CE directive 89/336/EEC an appropriate mains filter must be installed.
For MintDrives requiring the external 24VDC logic supply, a 24V filter must also be installed.
See page 18.
2.2.1
Dimensions and mounting
Ensure you have read and understood page 8. Mount the MintDrive on its rear side, the side opposite
to the front panel. The MintDrive must be mounted upright to ensure adequate cooling (you can check
this by ensuring that the Hazardous Voltages warning information is clearly readable to you). M5 bolts
or screws should be used to mount the unit.
Package
Current
A
2.5A
B
5A /
7.5A
C
10A /
15A
W
1
W
2
D
H1
H2
6.81
7.67
8.07
(173)
(195.5)
(205)
6.81
7.67
8.07
(173)
(195.5)
(205)
14.05
15.12
15.75
(357)
(384)
(400)
Figure 1 - Package dimensions
W
3
W
4
Dimensions inches (mm)
H3
W1
W2
0.6
0.6
(15)
(15)
0.9
0.9
(23)
(23)
1.1
0.37
(27.5)
(9.5)
Package A
2.5A
Package C
10A / 15A
Package B
5A / 7.5A
W3
W4
D
1.57
3.31
6.00
(40)
(84)
(152)
1.57
4.29
6.00
(40)
(109)
(152)
1.42
2.17
10.43
(36)
(55)
(265)
Weight
lb (kg)
4.89
(2.22)
5.31
(2.41)
9.92
(4.5)
9