5.3.3 PI Control Mode (P1-07 = 3)
Table 5-5 Parameter P1-08 Control of Digital Inputs when P1-07 = 3
Digital In 1
P1-08
(Term 2)
Open: Stop
0, 10, 13,
16, 18
Closed: Run
Open: Stop
11
Closed: Run
Open: Stop
12
Closed: Run
Open: Stop
17
Closed: Run
Open: Stop
19
Closed: Run
Open: Stop
20, 21
Closed: Run
Open: Stop
22
Closed: Run
Note: When P3-05 = 1, Bipolar analog input controls PID set point. The feedback must then be connected
to Analog input 2 and P3-10 must be set to 0 (Default setting). The external trip input only functions
when the feedback source is the Bipolar analog input (P3-10 = 1).
5-8 Control Wiring
Digital In 2
(Term 3)
No Function
Open: PID control
Closed: Preset Speed 1
Open: Preset Speed 1
Closed: PID control
Open: PID control
Closed: Bipolar analog
ref
Open: PID control
Closed: Analog input 2
Digital Output:
Drive Healthy = +24V
Digital Output:
Drive Healthy = +24V
Digital In 3
(Term 4)
Analog input 2
External trip input
Open: Trip
Closed: No Trip
External trip input
Open: Trip
Closed: No Trip
Analog input 2
Analog input 2
Analog input 2
External trip input
Open: Trip
Closed: No Trip
Analog Input
(Term 6)
Bipolar analog input
Bipolar analog input
Bipolar analog input
Bipolar analog input
Bipolar analog input
Bipolar analog input
Bipolar analog input