7.4.2 Application Specific Parameters
Table 7-7 Application Specific Parameters - Parameter Group 6
Par
Description
No.
Software
P6-01
Upgrade Enable
Thermal
P6-02
Management
Enable
Auto-Reset
P6-03
Delay Time
User Relay
P6-04
Speed
Hysteresis Band
Encoder
P6-05
Feedback Enable
P6-06 Encoder PPR
Encoder Speed
P6-07
Error Limit
MN762S
Range
Units
0: Disable
1: I/O En
-
2: DSP En
0: Disable
1: Enable
-
1s...60
s
0.0 ... 25.0
%
0: Disabled
1: Enabled
-
0 .. 10000
-
0.0 ... 50.0
%
Default
Explanation
Enables the Application Macro
0
loading / firmware upgrade
process.
When set to 1, the drive will
automatically reduce the output
switching frequency with
0
increasing heat sink temperature,
to reduce the risk of an over
temperature trip.
Sets the delay time allowed
between consecutive reset
20
attempts when Auto Reset is
enabled (see P2-17).
This parameter defines a band
around zero speed as a percentage
of P1-03. When P2-11 or P2-13 =
2 or 3, output frequencies below
this value are treated as 'zero
speed'. This function is used to
0.3
prevent "chatter" on the output if
the operating speed coincides with
the level at which the digital / relay
output changes state. E.g. if P2-13
= 3, P1-06 = 50Hz and P6-04 =
5%, the relay contacts close above
2.5Hz.
0
Enables Encoder Feedback.
Sets the number of Pulses Per
0
Revolution for the encoder
This parameter defines the allowed
speed error between the encoder
5.0
feedback and the VS1MXS own
estimated rotor speed. When set to
zero, the protection is disabled.