6.1 Keypad Components
This chapter provides an overview of the integrated keypad and how to use it to program the VS1MXS
drive. The controls are shown in Table 6-1.
Key
STOP
MN762S
Table 6-1 Operator Interface Description
Name
6 Digit seven segment display. Display of parameter
Display
numbers, values, error messages and other information.
Starts motor if Direction command and Speed reference
are set. Only active if P1-07 is set to allow keypad control.
Start
Programmable to change the motor direction if pressed
while running.
Stops the drive in all modes. Stop is always active and
stops the drive in both keypad, terminal and network
Stop / Reset
control modes. Resets any active faults, if fault condition
has been cleared.
Momentarily press to view available displays. Pressing and
holding the ENT Key for approximately 2 Seconds or more
Enter / Program
will enter the programming mode or escape back out of
the programming mode.
During operation increases the speed reference. (Active in
keypad mode). Pressing for a period of time will increase
Increase
the reference value rate of change. In edit mode, navigates
between parameters and increments parameter values.
During operation decreases the speed reference. (Active in
keypad mode). Pressing for a period of time will increase
Decrease
the reference value rate of change. In edit mode, navigates
between parameters and decrements parameter values.
Speed Reference
Adjusts the motor speed when Analog In1 is set as the
(Disconnect
Speed Reference Source.
models only)
Direction
Sets the direction of motor rotation and issues a run
Command
command, 0 (OFF), FWD (run forward) or REV (Run
(Disconnect
reverse). At 0 position, the motor output is disabled but
models only)
power is applied to the control circuits.
OFF removes power from internal circuits. On powers up
On/Off Power
the control for operation.
Switch
Note: In OFF, AC power is still present at the L1, L2, L3
(Disconnect
terminals. Separate disconnect required to remove AC
models only)
power from drive terminals.
On/Off Power Switch (with Lockout). Allows the On/Off
NEMA12 only
Power Switch to be locked in the OFF position using a
(Disconnect
20mm standard shackle pad lock (not provided). This
models only)
ensures no one will accidentally turn power on.