6.2 Using the REV/0/FWD Selector Switch

(Switched version only)
By adjusting the parameter settings the VS1MXS can be configured for multiple applications and not
just for Forward or Reverse. This could typically be for Hand/Off/Auto applications (also known and
Local/Remote) for HVAC and pumping industries.
Switch Position
OFF
REV
FWD
REV
STOP
Preset Speed
1
Run Reverse
Run in Speed
Control
Run in Speed
Control
Run in Hand
Run in Hand

6.3 Changing Parameters

To change a parameter value press and hold the
displays . The display changes to, indicating parameter 01. Press and release the ENT/
PROG key to display the value of this parameter.
Use the
UP and
the ENT/PROG key once more to store the change. Press and hold the ENT/PROG key for > 2 second
to return to operational mode. The display shows if the drive is stopped or the real-time
information (for example speed) if the drive is running.
6-2 Using the Keypad
Table 6-2 REV/0/FWD Switch Controls
OFF
OFF
FWD
REV
FWD
Run
STOP
Forward
Run
STOP
Forward
Run
STOP
Forward
Run in PID
STOP
Control
Run in PID
STOP
Control
Run in
STOP
Auto
Run in
STOP
Auto
DOWN arrow keys to change to the required value. Press and release
Parameters
P1-07
P1-08
Notes
0
0
Factory Default Configuration
Preset Speed 1 provides a 'Jog'
0
0
Speed
7, 8, 9,
0
10
In Speed Control, POT controls
speed
3
17
In PID Control, POT controls set point
In Speed Control, P2-1 sets the
Preset Speed
3
11
In PID Control, pot controls set point
Hand – Speed reference from Pot
4
17
Auto – Speed Reference from
Modbus
Hand – Speed reference from Preset
Speed 1
4
17
Auto – Speed Reference from
Modbus
ENT
ENT/PROG key for > 2 seconds while the drive
Notes