Setting Alarm Operation And Display - Sanyo DSR-3709 Instruction Manual

Digital video recorder with multiplexer system
Hide thumbs Also See for DSR-3709:
Table of Contents

Advertisement

3
RECORD SET
The period for "T-1" through "T-4" as set in step 9
changes to that of "TIME PERIOD A" or "TIME PERIOD
B" on P.57.
When time period is unset, T-1 settings are enabled
and T-2 through T-4 are disabled.
The sensitivity level can be checked using the setting
screen. When motion is detected, the sensor color
changes from green to red, and a buzzer is sounded.
If detection is too sensitive, an alarm can be triggered
even by slight changes in lighting; accordingly, the
sensitivity level should be set to match the camera
location.

Setting alarm operation and display

1
Press the [MENU] button and turn the
jog dial to select "2. RECORD SET", and
then turn the shuttle dial.
The <RECORD SET> screen is displayed.
MENU
2
Turn the jog dial to select "8. ALARM
OPERATION SET", and then turn the
shuttle dial clockwise.
The <ALARM OPERATION SET> screen is displayed with
the cursor positioned on "ALARM RETRIGGER".
3
Turn the shuttle dial clockwise.
"OFF" flashes in the "ALARM RETRIGGER" field.
<ALARM OPERATION SET>
ALARM RETRIGGER
: OFF
MAIN MON. DISPLAY
: NC
ALARM PRIORITY
: LAST
MON.2 DISPLAY
: OFF
84
4
Turn the jog dial to set the alarm trigger
to "ON", and then turn the shuttle dial
clockwise.
The cursor moves to "MAIN MON. DISPLAY".
[Settings] (
indicates default setting)
Setting
Even if a new alarm is received on the same channel
OFF
during alarm recording, the duration is not extended.
If a new alarm is received on the same channel during
alarm recording, the duration is extended and both
alarms are treated as one. (Example: Input in the alarm
sequence A → C) However, if the new alarm is on a
different channel, the alarms are treated separately.
(Example: Input in the alarm sequence A → B → C)
Example:
ON
Alarm
CH1
Alarm Recording A
Alarm
CH2
Setting alarm display
1
Turn the jog dial to select "MAIN MON.
DISPLAY", and then turn the shuttle dial
clockwise.
"NC" starts to flash for "MAIN MON. DISPLAY".
[Settings] (
indicates default setting)
Setting
When an alarm is detected, the video on the
FULL
channel containing the alarm is displayed in full
screen format on the main monitor.
When an alarm is detected, a multi-9 screen
9
display is presented on the main monitor.
When an alarm is detected, a multi-16 screen
16
display is presented on the main monitor. (This can
only be set on the DSR-3716.)
The main monitor's display does not change when
NC
an alarm is detected.
Description
Alarm
Alarm Recording C
Alarm Recording B
<ALARM OPERATION SET>
ALARM RETRIGGER
: ON
MAIN MON. DISPLAY
: NC
ALARM PRIORITY
: LAST
MON.2 DISPLAY
: OFF
Description
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr-3716

Table of Contents