Mitsubishi Electric QJ71DN91 User Manual page 22

Melsec system q programmable controller devicenet master-slave module gx configurator-dn
Hide thumbs Also See for QJ71DN91:
Table of Contents

Advertisement

2 SYSTEM CONFIGURATION
Q00J/Q00/Q01CPU
Q02/Q02H/Q06H/
Q12H/Q25HCPU
Q12PH/Q25PHCPU
Q02U/Q03UD/Q04U
DH/Q06UDHCPU
*1: Version 1.14Q or earlier does not support Node Communication Error Status (address : 01C0
2 - 4
(2) Support of the multiple CPU system
When using the QJ71DN91 in a multiple CPU system, refer to the QCPU User's
Manual (Multiple CPU System) first.
(a)
Compatible QJ71DN91
The function version of the first released QJ71DN91 is B, and it supports
multiple CPU systems.
(b)
Intelligent function module parameters
Write intelligent function module parameters to only the control CPU of the
QJ71DN91.
(3) Supported software packages
Relation between the system containing the QJ71DN91 and software package is
shown in the following table.
GX Developer is necessary when using the QJ71DN91.
Single CPU system
Multiple CPU system
Single CPU system
Multiple CPU system
Single CPU system
Multiple CPU system
Single CPU system
Multiple CPU system
to 01C3
/448 to 451). Please use Version 1.15R or later.
H
(4) Remote operation is not allowed from another DeviceNet node
Each DeviceNet node on DeviceNet cannot read/write/monitor the sequence
program or data of the programmable controller CPU where the QJ71DN91 is
installed.
Software version
GX Developer
Version 7 or later
Version 8 or later
Version 4 or later
Version 6 or later
Version 7.10L or later
Version 8.48A or later
MELSEC-Q
*1
GX Configurator-DN
Version 1.10L or later
Version 1.00A or later
Version 1.10B or later
Version 1.13P or later
Version 1.23Z or later
H
2 - 4

Advertisement

Table of Contents
loading

Table of Contents