62 | Hardware Cabling Guide
HIC
Data rate and
protocol
16 Gb/s Fibre
Channel
10 Gb/s iSCSI
1 Gb/s iSCSI
1
Optical cables for 1-Gb/s iSCSI connections require a 1-Gb/s SFP.
2
Copper cables with RJ-45 connectors for iSCSI connections require an SFP adapter.
The following table shows host cabling configurations for the E2600 controller-drive trays.
Cable
Number of
Connector
connectors
4
SFP+
SFP+
SFP+
2
SFP+
SFP+
SFP+
4
SFP+
SFP+
Twin-Ax
2
SFP+
SFP+
Twin-Ax
RJ-45
1
4
SFP+
1
SFP+
Twin-Ax
2
RJ-45
1
2
SFP+
1
SFP+
Twin-Ax
2
RJ-45
RJ-45
Type
Length
OM2 SW optical
2,3,5,10,25
m
OM3 SW optical
50-150m
OS2 LW optical
50-300m
OM2 SW optical
2,3,5,10,25
m
OM3 SW optical
50-150m
OS2 LW optical
50-300m
OM2 optical
2,3,5,10,25
m
OM3 optical
50-150m
passive copper
2-7m
OM2 optical
2,3,5,10,25
m
OM3 optical
50-150m
passive copper
2-7m
Cat6a passive copper 2-100m
OM2 optical
2, 3, 5, 10,
25m
OM3 optical
50-150m
passive copper
2-7m
passive copper
2-70m
OM2 optical
2, 3, 5, 10,
25m
OM3 optical
50-150m
passive copper
2-7m
Cat5 passive copper
2-70m
Cat6a passive copper 2-100m