Technical Data; Power Rating, Electrical Specifications And Noise Level - ergoline Beauty Angel 7200 Operating Instructions Manual

Hide thumbs Also See for Beauty Angel 7200:
Table of Contents

Advertisement

What this device is
Model-No.: JK 158 / BA 32-0 VS
Power consumption rating:
Rated frequency:
Rated voltage:
Rated overcurrent protection device
Power supply:
Classification:
Temperature of the foot mat
(after max. 9 min. application time):
Ingress protection classification:
Protection against electric shock:
Max. allowed network impedance:
Rated maximum output power
Noise level inside the device:
Noise level 1m away from device:
Load on the base plate: / foot mat, silicone:
Weight:
Max. humidity:
Ambient temperature:
Max. operating altitude (above sea level):
24/92
3.9

Technical data

3.9.1
Power rating, electrical specifications and
noise level
230 V 3 phase
30 amp 3-pole
4 x THHN AWG 10
Type BF applied part foot mat, silicone
if ambient temperature is 89,6 °F (32 °C)
NOTE:
Adaptation of the unit is required for operating altitudes
greater than 6,500 ft / 2,000 m above sea level in order to
guarantee trouble-free operation.
6100 W
60 Hz
or
or
maximum 119 °F (48 °C),
IP20
Class I
0.095 Ω
normal mode: 5.26 dBm (e.i.r.p.)
70 dB(A)
<71.6 dB(A)
max. 330 lb / 150 kg
approx. 1202 lb / 545 kg
70%
59-89,6°F (15-32 °C)
6,500 ft (2,000 m)
230 V 2 phase
40 amp 2-pole
3 x THHN AWG 10